| Literature DB >> 24107701 |
Tanmoy Ghatak1, Ratender Kumar Singh, Arvind Kumar Baronia.
Abstract
Internal jugular vein (IJV) catheterization is a routine technique in the intensive care unit. Ultrasound (US) guided central venous catheter (CVC) insertion is now the recommended standard. However, mechanical complications still occur due to non-visualization of the introducer needle tip during US guidance. This may result in arterial or posterior venous wall puncture or pneumothorax. We describe a new technique of (IJV) catheterization using US, initially the depth of the IJV from the skin is measured in short-axis and then using real time US long-axis view guidance a marked introducer needle is advanced towards the IJV to the defined depth measured earlier in the short axis and the IJV is identified, assessed and cannulated for the CVC insertion. Our technique is simple and may reduce mechanical complications of US guided CVC insertion.Entities:
Mesh:
Year: 2013 PMID: 24107701 DOI: 10.4103/0971-9784.119185
Source DB: PubMed Journal: Ann Card Anaesth ISSN: 0971-9784