Literature DB >> 24106170

Assessing near infrared optical properties of ceramic orthodontic brackets using cross-polarization optical coherence tomography.

Darren M Isfeld1, Conrado Aparicio, Robert S Jones.   

Abstract

Secondary decay (caries) under ceramic orthodontic brackets remains a significant dental problem and near infrared cross-polarization optical coherence tomography (CP-OCT) has the potential to detect underlying demineralization. The purpose of this study was to determine the effect of crystalline structure and chemical composition of ceramic brackets on CP-OCT imaging. Four ceramic brackets types, which were divided into monocrystalline and polycrystalline, were examined using CP-OCT. The results of this study demonstrated that the crystallinity of the ceramic brackets affected the 1310 nm CP-OCT imaging with the greatest attenuation seen in polycrystalline alumina brackets. The alumina polycrystalline bracket materials had significantly higher attenuation and scattering than alumina monocrystalline brackets (p < 0.05, ANOVA, Bonferroni). Additionally, bracket base morphology and composition affected NIR light attenuation. There was considerable attenuation in bracket bases that contained additive zirconium spheres (∼30 µm) and this alteration was significantly greater than the jagged alumina crystallographic alterations found in the other bracket systems (p < 0.05, ANOVA, Bonferroni). Noninvasive, near infrared (NIR) cross-polarization optical coherence tomography (CP-OCT) has potential to effectively image through portions of ceramic brackets; however, further investigation into the optical effects of resin integration in the base portion of the brackets is warranted.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  dental caries; dental ceramics; imaging systems; medical optics instrumentation; optical coherence tomography; polarization

Mesh:

Substances:

Year:  2013        PMID: 24106170     DOI: 10.1002/jbm.b.33029

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  3 in total

Review 1.  The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review.

Authors:  Monika Machoy; Julia Seeliger; Liliana Szyszka-Sommerfeld; Robert Koprowski; Tomasz Gedrange; Krzysztof Woźniak
Journal:  J Healthc Eng       Date:  2017-07-16       Impact factor: 2.682

2.  In vitro bond strengths post thermal and fatigue load cycling of sapphire brackets bonded with self-etch primer and evaluation of enamel damage.

Authors:  Ali I Ibrahim; Noor R Al-Hasani; Van P Thompson; Sanjukta Deb
Journal:  J Clin Exp Dent       Date:  2020-01-01

3.  Optimization of X-ray Investigations in Dentistry Using Optical Coherence Tomography.

Authors:  Ralph-Alexandru Erdelyi; Virgil-Florin Duma; Cosmin Sinescu; George Mihai Dobre; Adrian Bradu; Adrian Podoleanu
Journal:  Sensors (Basel)       Date:  2021-07-02       Impact factor: 3.847

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.