Jaime L Shaw1, Benjamin R Knowles, James W Goldfarb, Warren J Manning, Dana C Peters. 1. Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA; Department of Biomedical Sciences, Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
Abstract
PURPOSE: To compare two late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) methods: a Dixon LGE sequence with sequential phase-encoding order, reconstructed using water-fat separation, and standard fat-saturated LGE. MATERIALS AND METHODS: We implemented a dual-echo Dixon LGE method for reconstructing water-only images and compared it to fat-saturated LGE in 12 patients prior to their first pulmonary vein isolation (PVI) procedure. Images were analyzed for quality and fat-suppression. Regions of the left atrium were evaluated by a blinded observer (1 = prominent enhancement, 0 = mild or absent enhancement) on two sets of images (fat-saturated and water-only LGE) and agreement was assessed. RESULTS: Water-only LGE showed a trend toward better fat-suppression (P = 0.06), with a significantly more homogeneous blood pool signal and reduced inflow artifacts (both P < 0.01). Agreement between fat-saturated LGE and water-only methods was found in 84% of regions, significantly correlated by chi-squared test (P < 0.001). The kappa value was 0.52 (moderate). The average number of enhancing segments was higher for fat-saturated LGE than water-only LGE (4.2 ± 2.7 vs. 3.2 ± 2.9, P = 0.03). CONCLUSION: The two-point Dixon LGE technique reduces artifacts due to a centric k-space order. A similar enhancement pattern was observed irrespective of the LGE technique, with more enhancement detected by fat-saturated LGE.
PURPOSE: To compare two late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) methods: a Dixon LGE sequence with sequential phase-encoding order, reconstructed using water-fat separation, and standard fat-saturated LGE. MATERIALS AND METHODS: We implemented a dual-echo Dixon LGE method for reconstructing water-only images and compared it to fat-saturated LGE in 12 patients prior to their first pulmonary vein isolation (PVI) procedure. Images were analyzed for quality and fat-suppression. Regions of the left atrium were evaluated by a blinded observer (1 = prominent enhancement, 0 = mild or absent enhancement) on two sets of images (fat-saturated and water-only LGE) and agreement was assessed. RESULTS:Water-only LGE showed a trend toward better fat-suppression (P = 0.06), with a significantly more homogeneous blood pool signal and reduced inflow artifacts (both P < 0.01). Agreement between fat-saturated LGE and water-only methods was found in 84% of regions, significantly correlated by chi-squared test (P < 0.001). The kappa value was 0.52 (moderate). The average number of enhancing segments was higher for fat-saturated LGE than water-only LGE (4.2 ± 2.7 vs. 3.2 ± 2.9, P = 0.03). CONCLUSION: The two-point Dixon LGE technique reduces artifacts due to a centric k-space order. A similar enhancement pattern was observed irrespective of the LGE technique, with more enhancement detected by fat-saturated LGE.
Authors: O P Simonetti; R J Kim; D S Fieno; H B Hillenbrand; E Wu; J M Bundy; J P Finn; R M Judd Journal: Radiology Date: 2001-01 Impact factor: 11.105
Authors: Mehdi H Moghari; Dana C Peters; Jouke Smink; Lois Goepfert; Kraig V Kissinger; Beth Goddu; Thomas H Hauser; Mark E Josephson; Warren J Manning; Reza Nezafat Journal: Magn Reson Med Date: 2011-02-28 Impact factor: 4.668
Authors: R J Kim; D S Fieno; T B Parrish; K Harris; E L Chen; O Simonetti; J Bundy; J P Finn; F J Klocke; R M Judd Journal: Circulation Date: 1999-11-09 Impact factor: 29.690
Authors: Robert S Oakes; Troy J Badger; Eugene G Kholmovski; Nazem Akoum; Nathan S Burgon; Eric N Fish; Joshua J E Blauer; Swati N Rao; Edward V R DiBella; Nathan M Segerson; Marcos Daccarett; Jessiciah Windfelder; Christopher J McGann; Dennis Parker; Rob S MacLeod; Nassir F Marrouche Journal: Circulation Date: 2009-03-23 Impact factor: 29.690
Authors: Camila Munoz; Iain Sim; Radhouene Neji; Karl P Kunze; Pier-Giorgio Masci; Michaela Schmidt; Mark O'Neill; Steven Williams; René M Botnar; Claudia Prieto Journal: MAGMA Date: 2021-06-24 Impact factor: 2.310