Literature DB >> 24103066

Evaluation of the radiopacity of esthetic root canal posts.

Eliana Rodrigues1, Leda Maria Pescinini Salzedas, Alberto Carlos Botazzo Delbem, Denise Pedrini.   

Abstract

UNLABELLED: The radiopacity of esthetic root canal posts may impair the assessment of their fit to the root canal when using radiographic images. This study determined in vitro the radiographic density of esthetic root canal posts using digital images. Thirty-six roots of human maxillary canines were assigned to six groups (N=6 per group): Reforpost (RP); Aestheti-Plus (AP); Reforpost MIX (RPM); D.T. Light Post (LP); Reforpost Radiopaque (RPR); and White Post DC (WP). Standardized digital images of the posts were obtained in different conditions: outside the root canal, inside the canal before and after cementation using luting material, and with a tissue simulator. Analysis of variance was used to compare the radiopacity mean values among the posts outside the root canal and among the posts under the other conditions, and the "t" unpaired test to compare the radiopacity between the posts and the dentin, and between the posts and the root canal space. There was no statistically significant difference in radiopacity between RP and RPM, and LP and WP. AP posts showed radiopacity values significantly lower than those for dentin. No statistically significant difference was found between posts (RP and AP) and the root canal space. A statistically significant difference was observed between the luted and non-luted posts; additionally, luted posts with and without tissue simulator showed no significant differences. Most of the cement-luted posts analyzed in this study were distinguishable from the density of adjacent dentin surfaces, allowing radiographic confirmation of the fit of the post in the canal. CLINICAL SIGNIFICANCE: The success of using esthetic root canal posts depends mainly on the fit of the post within the canal.[1] The radiopacity of a post allows for radiographic imaging to be used to determine the fit, an important factor in a clinical perspective.
© 2013 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2013        PMID: 24103066     DOI: 10.1111/jerd.12059

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  1 in total

1.  A Comparative Evaluation of the Radiopacity of Contemporary Restorative CAD/CAM Blocks Using Digital Radiography Based on the Impact of Material Composition.

Authors:  Nahla Gamal Elhelbawy; Rehab F Ghouraba; Fatma A Hasaneen
Journal:  Int J Biomater       Date:  2022-02-21
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.