Literature DB >> 24095607

Contrast echocardiography to assess left ventricular volume and function in Beagle dogs: comparison with 3-Tesla dual source parallel cardiac magnetic resonance imaging.

J H Kim1, M S Lee, S Y Lee, S Y Kim, S Y Lee, S J Lee, Y W Park, J H Yeo, S H Song, N W Park, S W Hong, S I Choi, K D Eom.   

Abstract

This study was performed to evaluate the effect and feasibility of contrast echocardiography (CE) compared with unenhanced echocardiography (UE) and cardiac magnetic resonance imaging (CMRI) to assess left ventricular (LV) volume and function, including end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) in six healthy Beagles. When the dogs were conscious, LV measurements using CE were significantly higher than those obtained using UE, except for EF, and were similar to the values obtained using CMRI. Additionally, EDV, SV, and EF obtained using UE from anesthetized dogs were significantly lower than those obtained using CE or CMRI. Measurements of EDV, SV and EF using CE were not significantly different from the corresponding measurements obtained using CMRI (31.13±2.18 vs. 32.88±1.17 mL, 18.41±1.25 vs. 17.92±0.96 mL, 59.29±2.29% vs. 53.33±1.69%, respectively). Inter-observer agreements for UE (0.74±0.05) were lower than those for CE (0.80±0.04) and CMRI (0.92±0.03). In conclusion, LV function was assessed reproducibly using CE, and the measurements obtained were consistent with reference standard measurements obtained using CMRI. Measurements made using CE agreed more closely with CMRI than those made using UE.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cardiac magnetic resonance imaging; Contrast echocardiography; Dogs; Left ventricular measurement

Mesh:

Year:  2013        PMID: 24095607     DOI: 10.1016/j.tvjl.2013.08.007

Source DB:  PubMed          Journal:  Vet J        ISSN: 1090-0233            Impact factor:   2.688


  3 in total

1.  Effects of two different anesthetic protocols on cardiac flow measured by two dimensional phase contrast magnetic resonance imaging.

Authors:  Randi Drees; Rebecca A Johnson; Rebecca L Stepien; Alejandro Munoz Del Rio; Christopher J François
Journal:  Vet Radiol Ultrasound       Date:  2014-08-15       Impact factor: 1.363

2.  Contrast Echocardiography in two-dimensional left ventricular measurements: comparison with 256-row multi-detector computed tomography as a reference standard in Beagles.

Authors:  Jaehwan Kim; Soyoung Kim; Yeonhea Lee; Hakyoung Yoon; Kidong Eom
Journal:  J Vet Sci       Date:  2019-09       Impact factor: 1.672

3.  A novel cardiovascular systems model to quantify drugs effects on the inter-relationship between contractility and other hemodynamic variables.

Authors:  Yu Fu; Hadi Taghvafard; Medhat M Said; Eric I Rossman; Teresa A Collins; Stéphanie Billiald-Desquand; Derek Leishman; Piet H van der Graaf; J G Coen van Hasselt; Nelleke Snelder
Journal:  CPT Pharmacometrics Syst Pharmacol       Date:  2022-03-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.