Literature DB >> 24094441

[Reproducibility and accuracy in the morphometric and mechanical quantification of trabecular bone from 3 Tesla magnetic resonance images].

A Alberich-Bayarri1, L Martí-Bonmatí2, R Sanz-Requena3, J Sánchez-González4, V Hervás Briz3, G García-Martí5, M Á Pérez6.   

Abstract

OBJECTIVE: We used an animal model to analyze the reproducibility and accuracy of certain biomarkers of bone image quality in comparison to a gold standard of computed microtomography (μCT).
MATERIAL AND METHODS: We used magnetic resonance (MR) imaging and μCT to study the metaphyses of 5 sheep tibiae. The MR images (3 Teslas) were acquired with a T1-weighted gradient echo sequence and an isotropic spatial resolution of 180μm. The μCT images were acquired using a scanner with a spatial resolution of 7.5μm isotropic voxels. In the preparation of the images, we applied equalization, interpolation, and thresholding algorithms. In the quantitative analysis, we calculated the percentage of bone volume (BV/TV), the trabecular thickness (Tb.Th), the trabecular separation (Tb.Sp), the trabecular index (Tb.N), the 2D fractal dimension (D(2D)), the 3D fractal dimension (D(3D)), and the elastic module in the three spatial directions (Ex, Ey and Ez).
RESULTS: The morphometric and mechanical quantification of trabecular bone by MR was very reproducible, with percentages of variation below 9% for all the parameters. Its accuracy compared to the gold standard (μCT) was high, with errors less than 15% for BV/TV, D(2D), D(3D), and E(app)x, E(app)y and E(app)z.
CONCLUSIONS: Our experimental results in animals confirm that the parameters of BV/TV, D(2D), D(3D), and E(app)x, E(app)y and E(app)z obtained by MR have excellent reproducibility and accuracy and can be used as imaging biomarkers for the quality of trabecular bone.
Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.

Entities:  

Keywords:  Biomarcadores de imagen; Bones; Huesos; Imaging biomarkers; Magmetic resonance; Malla trabecular; Osteoporosis; Reproducibilidad de resultados; Reproducibility of results; Resonancia magnética; Trabecular meshwork

Mesh:

Year:  2013        PMID: 24094441     DOI: 10.1016/j.rx.2013.06.001

Source DB:  PubMed          Journal:  Radiologia        ISSN: 0033-8338


  4 in total

1.  MR imaging pattern of tibial subchondral bone structure: considerations of meniscal coverage and integrity.

Authors:  Aticha Ariyachaipanich; Emel Kaya; Sheronda Statum; Reni Biswas; Betty Tran; Won C Bae; Christine B Chung
Journal:  Skeletal Radiol       Date:  2020-06-26       Impact factor: 2.199

2.  Effects of Virgin Olive Oil on Bone Health in Ovariectomized Rats.

Authors:  Manuel Díaz-Curiel; Blanca Torrubia; Marta Martín-Fernández; Mercedes Rubert; Concepción De la Piedra
Journal:  Nutrients       Date:  2020-04-30       Impact factor: 5.717

3.  Reiterative infusions of MSCs improve pediatric osteogenesis imperfecta eliciting a pro-osteogenic paracrine response: TERCELOI clinical trial.

Authors:  Arantza Infante; Blanca Gener; Miguel Vázquez; Nerea Olivares; Arantza Arrieta; Gema Grau; Isabel Llano; Luis Madero; Ana Maria Bueno; Belén Sagastizabal; Daniela Gerovska; Marcos J Araúzo-Bravo; Itziar Astigarraga; Clara I Rodríguez
Journal:  Clin Transl Med       Date:  2021-01

4.  Trophic effects of multiple administration of mesenchymal stem cells in children with osteogenesis imperfecta.

Authors:  Sowmya Ramesh; Dolly Daniel; Cecilia Götherström; Vrisha Madhuri
Journal:  Clin Transl Med       Date:  2021-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.