Literature DB >> 24093708

Endo-Modell rotating-hinge total knee for revision total knee arthroplasty.

Alessandro Bistolfi, Federica Rosso, Maurizio Crova, Giuseppe Massazza.   

Abstract

The goal of this study was to analyze the clinical and radiographic results and the survival rate of a series of rotating-hinge implants used for revision total knee arthroplasties in mild and severe instability. Between December 1991 and June 2004, fifty-three revision total knee arthroplasties were performed using the Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) rotating-hinge prosthesis; 7 (13.2%) patients underwent partial revision of a previous Endo-Modell. All patients were evaluated preoperatively, 3 and 6 months postoperatively, and annually thereafter using the Hospital for Special Surgery (HSS) knee score and the Knee Society Roentgenographic Evaluation System (KS-RES). Mean follow-up was 155.2±40.1 months (range, 78-240 months), with 32 patients examined at the final follow-up. All HSS knee scores increased from preoperatively to last follow-up. No statistically significance differences were found in the HSS knee scores between septic and aseptic revisions and between total or partial revisions. Progressive radiolucent lines were detected in 8 (25%) patients. Implant failure occurred in 11 (20.7%) patients; the cumulative survival of the implants was 80.4% at 150 months for the final 32 patients. The authors recommend use of this implant for revision total knee arthroplasty, especially in patients with severe instability and bone loss. Copyright 2013, SLACK Incorporated.

Entities:  

Mesh:

Year:  2013        PMID: 24093708     DOI: 10.3928/01477447-20130920-24

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  5 in total

1.  Can Good Infection Control Be Obtained in One-stage Exchange of the Infected TKA to a Rotating Hinge Design? 10-year Results.

Authors:  Akos Zahar; Daniel O Kendoff; Till O Klatte; Thorsten A Gehrke
Journal:  Clin Orthop Relat Res       Date:  2016-01       Impact factor: 4.176

2.  KNEE ARTHROPLASTY REVISION WITH A CONSTRAINED IMPLANT USING HINGE AND ROTATING TIBIAL BASIS.

Authors:  Fabio Jansen Angelini; Camilo Partezani Helito; Bruno Azevedo Veronesi; Tales Mollica Guimarães; José Ricardo Pécora; Marco Kawamura Demange
Journal:  Acta Ortop Bras       Date:  2016 Jan-Feb       Impact factor: 0.513

Review 3.  Dislocation of rotating-hinge total knee arthroplasty.

Authors:  Carlos A Encinas-Ullán; Primitivo Gómez-Cardero; Juan S Ruiz-Pérez; E Carlos Rodríguez-Merchán
Journal:  EFORT Open Rev       Date:  2021-02-01

4.  Implant survivorship, functional outcomes and complications with the use of rotating hinge knee implants: a systematic review.

Authors:  Joshua Xu; Lennart von Fritsch; Shiraz A Sabah; Andrew J Price; Abtin Alvand
Journal:  Knee Surg Relat Res       Date:  2022-03-04

Review 5.  Total knee arthroplasty using hinge joints: Indications and results.

Authors:  E Carlos Rodríguez-Merchán
Journal:  EFORT Open Rev       Date:  2019-04-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.