Literature DB >> 24091201

A new marker for myocardial injury in carbon monoxide poisoning: T peak-T end.

Nazire Belgin Akilli1, Emine Akinci, Hakan Akilli, Zerrin Defne Dundar, Ramazan Koylu, Mustafa Polat, Basar Cander.   

Abstract

OBJECTIVES: Carbon monoxide (CO) poisoning frequently affects repolarization, resulting in abnormal electrocardiography findings. The goal of this study was to examine the effect of CO poisoning on the novel transmyocardial repolarization parameters T peak-T end (Tp-e), Tp-e dispersion, and Tp-e/QT and the relationship of these parameters to myocardial injury (MI).
METHODS: This prospective study included 94 patients with CO poisoning and 40 healthy controls. Participants received an electrocardiography and had their blood drawn at admission and 6 and 24 hours after admission. The QT, Tp-e, Tp-e dispersion, and the Tp-e/QT ratio were calculated. Myocardial injury was determined based on an elevation in troponin any time during the first 24 hours. The patients were divided into 2 subgroups: those with and without MI.
RESULTS: T peak-T end, Tp-e dispersion, and the Tp-e/QT ratio were higher at admission than after 6 and 24 hours of hospitalization and were higher than the control group (P < .001). There was a correlation between the carboxyhemoglobin level at admission and Tp-e and Tp-e dispersion (P < .001). The MI subgroup (n = 14) had a higher Tp-e at admission than did the non-MI subgroup (n = 80) (96 [11] milliseconds vs 87 [12] milliseconds, P = .03). There were no any significant differences in the Tp-e dispersion or the Tp-e/QT ratio between the 2 MI subgroups. Receiver operating characteristic analysis showed that a Tp-e cutoff value for MI of 91.5 milliseconds had a sensitivity of 72.7% and a specificity of 67.2%.
CONCLUSION: Transmyocardial repolarization parameters indicative of arrhythmia were prolonged in patients with CO poisoning. T peak-T end was associated with MI.
© 2013.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24091201     DOI: 10.1016/j.ajem.2013.08.049

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  4 in total

1.  Evaluation of the relationship between the level of addiction and exhaled carbon monoxide levels with QT dispersion in smokers.

Authors:  Gamze Keskin; Sibel Tunç Karaman; Okcan Basat
Journal:  Tob Induc Dis       Date:  2021-03-31       Impact factor: 2.600

2.  Investigation of the Value of T peak to T end and QTc Intervals as Electrocardiographic Arrhythmia Susceptibility Markers in Acute Ischemic Stroke.

Authors:  Sedat Bılge; Onur Tezel; Yahya Ayhan Acar; Ferhat Cüce; Ömer Karadaş; Mustafa Taşar
Journal:  Noro Psikiyatr Ars       Date:  2020-01-24       Impact factor: 1.339

3.  Prognostic value of Tpeak-Tend interval in patients with acute pulmonary embolism.

Authors:  Abdullah Icli; Mehmet Kayrak; Hakan Akilli; Alpay Aribas; Mukremin Coskun; Sumeyye Fatma Ozer; Kurtulus Ozdemir
Journal:  BMC Cardiovasc Disord       Date:  2015-09-03       Impact factor: 2.298

4.  Predictive Role of QTc Prolongation in Carbon Monoxide Poisoning-Related Delayed Neuropsychiatric Sequelae.

Authors:  Shu-Chen Liao; Yan-Chiao Mao; Yao-Min Hung; Ching-Hsing Lee; Chen-Chang Yang
Journal:  Biomed Res Int       Date:  2018-09-25       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.