Literature DB >> 24090753

Rapid immuno-analytical system physically integrated with lens-free CMOS image sensor for food-borne pathogens.

Jin-Woo Jeon1, Jee-Hyun Kim, Jong-Mook Lee, Won-Ho Lee, Do-Young Lee, Se-Hwan Paek.   

Abstract

To realize an inexpensive, pocket-sized immunosensor system, a rapid test devise based on cross-flow immuno-chromatography was physically combined with a lens-free CMOS image sensor (CIS), which was then applied to the detection of the food-borne pathogen, Salmonella typhimurium (S. typhimurium). Two CISs, each retaining 1.3 mega pixel array, were mounted on a printed circuit board to fabricate a disposable sensing module, being connectable with a signal detection system. For the bacterial analysis, a cellulose membrane-based immunosensing platform, ELISA-on-a-chip (EOC), was employed, being integrated with the CIS module, and the antigen-antibody reaction sites were aligned with the respective sensor. In such sensor construction, the chemiluminescent signals produced from the EOC are transferred directly into the sensors and are converted to electric signals on the detector. The EOC-CIS integrated sensor was capable of detecting a traceable amount of the bacterium (4.22 × 10(3)CFU/mL), nearly comparable to that adopting a sophisticated detector such as cooled-charge-coupled device, while having greatly reduced dimensions and cost. Upon coupling with immuno-magnetic separation, the sensor showed an additional 67-fold enhancement in the detection limit. Furthermore, a real sample test was carried out for fish muscles inoculated with a sample of 3.3CFU S. typhimurium per 10 g, which was able to be detected earlier than 6h after the onset of pre-enrichment by culture.
© 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  CMOS image sensor; Chemiluminescent ELISA-on-a-chip; Food-borne pathogen; Immuno-magnetic separation; Portable immunosensor system

Mesh:

Year:  2013        PMID: 24090753     DOI: 10.1016/j.bios.2013.09.004

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  A Review of Membrane-Based Biosensors for Pathogen Detection.

Authors:  Remko van den Hurk; Stephane Evoy
Journal:  Sensors (Basel)       Date:  2015-06-15       Impact factor: 3.576

Review 2.  The Application of Lipid Membranes in Biosensing.

Authors:  Georgia-Paraskevi Nikoleli; Dimitrios P Nikolelis; Christina G Siontorou; Marianna-Thalia Nikolelis; Stephanos Karapetis
Journal:  Membranes (Basel)       Date:  2018-11-14

3.  Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate as a Tracer.

Authors:  Guei-Sam Lim; Sung-Min Seo; Sung-Ho Paek; Seung-Wan Kim; Jin-Woo Jeon; Dong-Hyung Kim; Il-Hoon Cho; Se-Hwan Paek
Journal:  Sci Rep       Date:  2015-10-07       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.