Literature DB >> 24090060

Dual LC-MS platform for high-throughput proteome analysis.

Dennis J Orton1, Mark J Wall, Alan A Doucette.   

Abstract

We describe a dual-column interface for parallel chromatography to improve throughput during LC-MS experimentation. The system employs a high-voltage switch to operate two capillary column/nanospray emitters fixed at the MS orifice. Sequentially loading one column while operating the second nearly doubles the LC-MS duty cycle. Given the innate run-to-run variation of a nanospray LC-MS (12% RSD peak area; 2% retention time), the intercolumn variability of the platform showed no meaningful difference for proteome analysis, with equal numbers of proteins and peptides identified per column. Applied to GeLC analysis of an E. coli extract, throughput was increased using one of three methods: doubling the number of replicates, increasing the LC gradient length, or sectioning the gel into twice as many fractions. Each method increased the total number of identifications as well as detection throughput (number of peptides/proteins identified per hour). The greatest improvement was achieved by doubling the number of gel slices (10 vs 5). Analysis on the dual column platform provided a 26% increase in peptides identified per hour (24% proteins). This translates into ~50% more total proteins and peptides identified in the experiment using the dual LC-MS platform.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24090060     DOI: 10.1021/pr400738a

Source DB:  PubMed          Journal:  J Proteome Res        ISSN: 1535-3893            Impact factor:   4.466


  2 in total

1.  Label-Free Profiling of up to 200 Single-Cell Proteomes per Day Using a Dual-Column Nanoflow Liquid Chromatography Platform.

Authors:  Kei G I Webber; Thy Truong; S Madisyn Johnston; Sebastian E Zapata; Yiran Liang; Jacob M Davis; Alexander D Buttars; Fletcher B Smith; Hailey E Jones; Arianna C Mahoney; Richard H Carson; Andikan J Nwosu; Jacob L Heninger; Andrey V Liyu; Gregory P Nordin; Ying Zhu; Ryan T Kelly
Journal:  Anal Chem       Date:  2022-04-06       Impact factor: 8.008

2.  A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day.

Authors:  Fabian Hosp; Richard A Scheltema; H Christian Eberl; Nils A Kulak; Eva C Keilhauer; Korbinian Mayr; Matthias Mann
Journal:  Mol Cell Proteomics       Date:  2015-04-17       Impact factor: 5.911

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.