Literature DB >> 24088581

Rapid and Sensitive Detection of H1N1/2009 Virus from Aerosol Samples with a Microfluidic Immunosensor.

Hyuck-Jin Kwon1, Christopher F Fronczek2, Scott V Angus3, Ariana M Nicolini2, Jeong-Yeol Yoon4.   

Abstract

Influenza A H1N1/2009 is a highly infectious, rapidly spreading airborne disease that needs to be monitored in near real time, preferably in a microfluidic format. However, such demonstration is difficult to find as H1N1 concentration in aerosol samples is extremely low, with interference from dust particles. In this work, we measured Mie scatter intensities from a microfluidic device with optical waveguide channels, where the antibody-conjugated latex beads immunoagglutinated with the target H1N1 antigens. Through careful optimizations of optical parameters, we were able to maximize the Mie scatter increase from the latex immunoagglutinations while minimizing the background scatter from the dust particles. The aerosol samples were collected from a 1:10 mock classroom using a button air sampler, where a nebulizer generated aerosols, simulating human coughing. The detection limits with real aerosol samples were 1 and 10 pg/mL, using a spectrometer or a cell phone camera as an optical detector, respectively. These are several orders of magnitudes more sensitive than the other methods. The microfluidic immunosensor readings are in concordance with the results of reverse transcription polymerase chain reaction. The assay time was 30 s for sampling and 5 min for the microfluidic assay.
© 2013 Society for Laboratory Automation and Screening.

Entities:  

Keywords:  aerosol; cell phone camera; immunoagglutination; influenza A; liquid-core waveguide

Mesh:

Substances:

Year:  2013        PMID: 24088581     DOI: 10.1177/2211068213504205

Source DB:  PubMed          Journal:  J Lab Autom        ISSN: 2211-0682


  3 in total

Review 1.  Lab-on-a-Chip Platforms for Airborne Particulate Matter Applications: A Review of Current Perspectives.

Authors:  Sharon Ezrre; Marco A Reyna; Citlalli Anguiano; Roberto L Avitia; Heriberto Márquez
Journal:  Biosensors (Basel)       Date:  2022-03-24

Review 2.  Recent advancements in the measurement of pathogenic airborne viruses.

Authors:  Jyoti Bhardwaj; Seongkyeol Hong; Junbeom Jang; Chang-Ho Han; Jaegil Lee; Jaesung Jang
Journal:  J Hazard Mater       Date:  2021-07-05       Impact factor: 10.588

3.  Detection of airborne viruses using electro-aerodynamic deposition and a field-effect transistor.

Authors:  Kyu-Tae Park; Dong-Guk Cho; Ji-Woon Park; Seunghun Hong; Jungho Hwang
Journal:  Sci Rep       Date:  2015-12-08       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.