Literature DB >> 24080132

Strategies for prevention of iatrogenic inferior vena cava filter entrapment and dislodgement during central venous catheter placement.

Alex Wu1, Naseem Helo1, Eunice Moon1, Matthew Tam2, Baljendra Kapoor1, Weiping Wang3.   

Abstract

BACKGROUND: Iatrogenic migration of inferior vena cava (IVC) filters is a potentially life-threatening complication that can arise during blind insertion of central venous catheters when the guide wire becomes entangled with the filter. In this study, we reviewed the occurrence of iatrogenic migration of IVC filters in the literature and assessed methods for preventing this complication.
METHODS: A literature search was conducted to identify reports of filter/wire entrapment and subsequent IVC filter migration. Clinical outcomes and complications were identified.
RESULTS: A total of 38 cases of filter/wire entrapment were identified. All of these cases involved J-tip guide wires. Filters included 23 Greenfield filters, 14 VenaTech filters, and one TrapEase filter. In 18 cases of filter/wire entrapment, there was migration of the filter to the heart and other central venous structures. Retrieval of the migrated filter was successful in only four of the 18 cases, and all of these cases were complicated by strut fracture and distant embolization of fragments. One patient required resuscitation during retrieval. Successful disengagement was possible in 20 cases without filter migration.
CONCLUSIONS: Iatrogenic migration of an IVC filter is an uncommon complication related to wire/filter entrapment. This complication can be prevented with knowledge of the patient's history, use of proper techniques when placing a central venous catheter, identification of wire entrapment at an early stage, and use of an appropriate technique to disengage an entrapped wire.
Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 24080132     DOI: 10.1016/j.jvs.2013.07.116

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  3 in total

Review 1.  Management of venous thromboembolism: an update.

Authors:  Siavash Piran; Sam Schulman
Journal:  Thromb J       Date:  2016-10-04

2.  Migration of an Inferior Vena Cava (IVC) Filter Into the Intrahepatic IVC: A Case Report.

Authors:  Alexis Gazda; Marc Squillante
Journal:  Cureus       Date:  2022-06-24

3.  Malposition of Central Venous Catheter: Presentation and Management.

Authors:  Lin Wang; Zhang-Suo Liu; Chang-An Wang
Journal:  Chin Med J (Engl)       Date:  2016-01-20       Impact factor: 2.628

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.