Literature DB >> 24080075

Noise levels in primary schools of medium sized city in Greece.

George Sarantopoulos1, Spyros Lykoudis2, Pavlos Kassomenos3.   

Abstract

This study presents and evaluates noise levels recorded at 15 school complexes in order to describe the indoor as well as the outdoor acoustic environment of schools and gain insight on controlling factors. Noise levels at the roadside in front of the school, the schoolyard, and 41 classrooms, both occupied and unoccupied, were simultaneously and continuously recorded through the course of a daily timetable (08:20-13:10). The average speech noise level of teachers was separately measured for 1min periods. Indoor noise levels, in all cases, were much higher than internationally recommended values: LAeq,5min averaged 69.0dB in occupied classrooms, and 47.1dB in unoccupied ones. Average speech-to-noise ratio (SNR) was estimated to be 12.0dB(A) during teaching, whereas both indoor and outdoor noise levels were significantly elevated during break time and outdoor physical-educational activities. Corresponding measurements of indoor and outdoor noise suggest that noise from the outside (road and schoolyard) affects the background noise level in the classrooms, however in varying degrees, depending on the specific layout and road traffic characteristics. Using double glazing diminishes this effect.
© 2013.

Keywords:  Background noise; Classroom; Noise levels; Primary school; Speech to Noise Ratio

Mesh:

Year:  2013        PMID: 24080075     DOI: 10.1016/j.scitotenv.2013.09.010

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  4 in total

1.  Assessment of ventilation noise impact from metro depot with over-track platform structure on workers and nearby inhabitants.

Authors:  Ziyu Tao; Yimin Wang; Chao Zou; Qi Li; Yue Luo
Journal:  Environ Sci Pollut Res Int       Date:  2019-02-04       Impact factor: 4.223

2.  Prevalence of Noise-Induced Hearing Loss Among Tanzanian Iron and Steel Workers: A Cross-Sectional Study.

Authors:  Israel P Nyarubeli; Alexander M Tungu; Bente E Moen; Magne Bråtveit
Journal:  Int J Environ Res Public Health       Date:  2019-04-16       Impact factor: 3.390

3.  Restricted Speech Recognition in Noise and Quality of Life of Hearing-Impaired Children and Adolescents With Cochlear Implants - Need for Studies Addressing This Topic With Valid Pediatric Quality of Life Instruments.

Authors:  Maria Huber; Clara Havas
Journal:  Front Psychol       Date:  2019-09-12

4.  Modeling Associations between Principals' Reported Indoor Environmental Quality and Students' Self-Reported Respiratory Health Outcomes Using GLMM and ZIP Models.

Authors:  Oluyemi Toyinbo; Markus Matilainen; Mari Turunen; Tuula Putus; Richard Shaughnessy; Ulla Haverinen-Shaughnessy
Journal:  Int J Environ Res Public Health       Date:  2016-03-30       Impact factor: 3.390

  4 in total