Literature DB >> 24078270

Parametric control of collision rates and capture rates in geometrically enhanced differential immunocapture (GEDI) microfluidic devices for rare cell capture.

James P Smith, Timothy B Lannin, Yusef Syed, Steven M Santana, Brian J Kirby.   

Abstract

The enrichment and isolation of rare cells from complex samples, such as circulating tumor cells (CTCs) from whole blood, is an important engineering problem with widespread clinical applications. One approach uses a microfluidic obstacle array with an antibody surface functionalization to both guide cells into contact with the capture surface and to facilitate adhesion; geometrically enhanced differential immunocapture is a design strategy in which the array is designed to promote target cell–obstacle contact and minimize other interactions (Gleghorn et al. 2010; Kirby et al. 2012). We present a simulation that uses capture experiments in a simple Hele-Shaw geometry (Santana et al. 2012) to inform a target-cell-specific capture model that can predict capture probability in immunocapture microdevices of any arbitrary complex geometry. We show that capture performance is strongly dependent on the array geometry, and that it is possible to select an obstacle array geometry that maximizes capture efficiency (by creating combinations of frequent target cell–obstacle collisions and shear stress low enough to support capture), while simultaneously enhancing purity by minimizing nonspecific adhesion of both smaller contaminant cells (with infrequent cell–obstacle collisions) and larger contaminant cells (by focusing those collisions into regions of high shear stress).

Entities:  

Mesh:

Year:  2014        PMID: 24078270      PMCID: PMC3969393          DOI: 10.1007/s10544-013-9814-4

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  27 in total

1.  Computational fluid dynamic studies of leukocyte adhesion effects on non-Newtonian blood flow through microvessels.

Authors:  B Das; P C Johnson; A S Popel
Journal:  Biorheology       Date:  2000       Impact factor: 1.875

Review 2.  Molecular properties in cell adhesion: a physical and engineering perspective.

Authors:  C E Orsello; D A Lauffenburger; D A Hammer
Journal:  Trends Biotechnol       Date:  2001-08       Impact factor: 19.536

3.  Computational modeling of cell adhesion and movement using a continuum-kinetics approach.

Authors:  N A N'Dri; W Shyy; R Tran-Son-Tay
Journal:  Biophys J       Date:  2003-10       Impact factor: 4.033

4.  Critical particle size for fractionation by deterministic lateral displacement.

Authors:  David W Inglis; John A Davis; Robert H Austin; James C Sturm
Journal:  Lab Chip       Date:  2006-03-17       Impact factor: 6.799

5.  Portable filter-based microdevice for detection and characterization of circulating tumor cells.

Authors:  Henry K Lin; Siyang Zheng; Anthony J Williams; Marija Balic; Susan Groshen; Howard I Scher; Martin Fleisher; Walter Stadler; Ram H Datar; Yu-Chong Tai; Richard J Cote
Journal:  Clin Cancer Res       Date:  2010-09-28       Impact factor: 12.531

6.  Soft inertial microfluidics for high throughput separation of bacteria from human blood cells.

Authors:  Zhigang Wu; Ben Willing; Joakim Bjerketorp; Janet K Jansson; Klas Hjort
Journal:  Lab Chip       Date:  2009-02-13       Impact factor: 6.799

Review 7.  The reaction-limited kinetics of membrane-to-surface adhesion and detachment.

Authors:  M Dembo; D C Torney; K Saxman; D Hammer
Journal:  Proc R Soc Lond B Biol Sci       Date:  1988-06-22

8.  Isolation and characterization of circulating tumor cells from patients with localized and metastatic prostate cancer.

Authors:  Shannon L Stott; Richard J Lee; Sunitha Nagrath; Min Yu; David T Miyamoto; Lindsey Ulkus; Elizabeth J Inserra; Matthew Ulman; Simeon Springer; Zev Nakamura; Alessandra L Moore; Dina I Tsukrov; Maria E Kempner; Douglas M Dahl; Chin-Lee Wu; A John Iafrate; Matthew R Smith; Ronald G Tompkins; Lecia V Sequist; Mehmet Toner; Daniel A Haber; Shyamala Maheswaran
Journal:  Sci Transl Med       Date:  2010-03-31       Impact factor: 17.956

9.  Capture of circulating tumor cells from whole blood of prostate cancer patients using geometrically enhanced differential immunocapture (GEDI) and a prostate-specific antibody.

Authors:  Jason P Gleghorn; Erica D Pratt; Denise Denning; He Liu; Neil H Bander; Scott T Tagawa; David M Nanus; Paraskevi A Giannakakou; Brian J Kirby
Journal:  Lab Chip       Date:  2009-11-16       Impact factor: 6.799

10.  Leukocytes roll on a selectin at physiologic flow rates: distinction from and prerequisite for adhesion through integrins.

Authors:  M B Lawrence; T A Springer
Journal:  Cell       Date:  1991-05-31       Impact factor: 41.582

View more
  8 in total

1.  Enhancing sensitivity and specificity in rare cell capture microdevices with dielectrophoresis.

Authors:  James P Smith; Chao Huang; Brian J Kirby
Journal:  Biomicrofluidics       Date:  2015-02-10       Impact factor: 2.800

2.  Tumor cell capture patterns around aptamer-immobilized microposts in microfluidic devices.

Authors:  Kangfu Chen; Teodor Z Georgiev; Weian Sheng; Xiangjun Zheng; Jose I Varillas; Jinling Zhang; Z Hugh Fan
Journal:  Biomicrofluidics       Date:  2017-10-02       Impact factor: 2.800

3.  Characterization of microfluidic shear-dependent epithelial cell adhesion molecule immunocapture and enrichment of pancreatic cancer cells from blood cells with dielectrophoresis.

Authors:  Chao Huang; James P Smith; Trisha N Saha; Andrew D Rhim; Brian J Kirby
Journal:  Biomicrofluidics       Date:  2014-07-21       Impact factor: 2.800

4.  Integration of Lateral Filter Arrays with Immunoaffinity for Circulating-Tumor-Cell Isolation.

Authors:  Kangfu Chen; Pablo Dopico; Jose Varillas; Jinling Zhang; Thomas J George; Z Hugh Fan
Journal:  Angew Chem Int Ed Engl       Date:  2019-05-09       Impact factor: 15.336

Review 5.  Circulating Tumor Cell Isolation and Analysis.

Authors:  J Zhang; K Chen; Z H Fan
Journal:  Adv Clin Chem       Date:  2016-04-21       Impact factor: 5.394

Review 6.  Recent Progress of Microfluidics in Translational Applications.

Authors:  Zongbin Liu; Xin Han; Lidong Qin
Journal:  Adv Healthc Mater       Date:  2016-03-22       Impact factor: 9.933

7.  Single-cell RNA sequencing reveals B cell-related molecular biomarkers for Alzheimer's disease.

Authors:  Liu-Lin Xiong; Lu-Lu Xue; Ruo-Lan Du; Jia Liu; Chang-Yin Yu; Ting-Hua Wang; Rui-Ze Niu; Li Chen; Jie Chen; Qiao Hu; Ya-Xin Tan; Hui-Fang Shang
Journal:  Exp Mol Med       Date:  2021-12-08       Impact factor: 12.153

8.  Incorporation of lateral microfiltration with immunoaffinity for enhancing the capture efficiency of rare cells.

Authors:  Kangfu Chen; Jacob Amontree; Jose Varillas; Jinling Zhang; Thomas J George; Z Hugh Fan
Journal:  Sci Rep       Date:  2020-08-26       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.