Literature DB >> 24077412

Percutaneous Pedicle Screw Placement in the Lumbar Spine: A Comparison Study Between the Novel Guidance System and the Conventional Fluoroscopy Method.

Guangfei Gu1, Hailong Zhang, Shisheng He, Xiaobing Cai, Xin Gu, Jianbo Jia, Qingsong Fu, Xu Zhou.   

Abstract

STUDY
DESIGN: The clinical study was conducted on 145 patients who received either a novel guidance method or a conventional fluoroscopic method for the percutaneous pedicle screw placement in the lumbar spine.
OBJECTIVE: The aim of this study was to introduce a novel guidance method for percutaneous pedicle screw placement and to compare it with the conventional fluoroscopic method. SUMMARY OF BACKGROUND DATA: Conventional fluoroscopic method was associated with a long screw placement and a more fluoroscopy time. The novel guidance system effectively minimized the insertion and the radiation exposure times.
METHODS: A total of 145 patients were divided into 2 groups. A total of 65 patients (group A) underwent 152 percutaneous pedicle screw fixation by conventional fluoroscopic method. A total of 80 patients (group B) underwent 185 percutaneous pedicle screw fixation by a novel guidance method. Age, body mass index, and sex ratio were comparable between the 2 groups (P>0.05). The time of insertion, radiation exposure, and accuracy of the screw placement between the 2 groups were compared.
RESULTS: The mean time for a single pedicle screw placement was found to be 15.11±3.32 minutes in group A and 10.35±2.82 minutes in group B, respectively. The average radiation exposure was 9.06±2.15 s in group B and 13.07±3.06 s in group A, respectively. The differences were statistically significant for both screw placement and radiation exposure times (P<0.05). A total of 131 screws (86.2%) in group A and 163 screws (88.1%) in group B were perfectly located within the pedicle. The statistical difference was not significant (χ=0.277, P=0.598).
CONCLUSIONS: The novel guidance system significantly reduced the insertion time and radiation exposure, provided the screw placement was accurately performed when compared with the conventional method.

Entities:  

Mesh:

Year:  2015        PMID: 24077412     DOI: 10.1097/BSD.0b013e3182aab222

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  9 in total

1.  Percutaneous pedicle screw placements: accuracy and rates of cranial facet joint violation using conventional fluoroscopy compared with intraoperative three-dimensional computed tomography computer navigation.

Authors:  Tetsuro Ohba; Shigeto Ebata; Koji Fujita; Hironao Sato; Hirotaka Haro
Journal:  Eur Spine J       Date:  2016-03-08       Impact factor: 3.134

Review 2.  Percutaneous screw placement in the lumbar spine with a modified guidance technique based on 3D CT navigation system.

Authors:  Ioannis D Siasios; John Pollina; Asham Khan; Vassilios George Dimopoulos
Journal:  J Spine Surg       Date:  2017-12

Review 3.  Reinforcement of Percutaneous Pedicle Screw Fixation with Hydroxyapatite Granules in Patients with Osteoporotic Spine: Biomechanical Performance and Clinical Outcomes.

Authors:  Haruo Kanno; Yoshito Onoda; Ko Hashimoto; Toshimi Aizawa; Hiroshi Ozawa
Journal:  Medicina (Kaunas)       Date:  2022-04-23       Impact factor: 2.948

4.  Comparison of bilateral versus unilateral decompression incision of minimally invasive transforaminal lumbar interbody fusion in two-level degenerative lumbar diseases.

Authors:  Yongzhao Zhao; Yanjie Zhu; Hailong Zhang; Chuanfeng Wang; Shisheng He; Guangfei Gu
Journal:  Int Orthop       Date:  2018-05-13       Impact factor: 3.075

5.  A comparison of three different surgery approaches and methods for neurologically intact thoracolumbar fractures: a retrospective study.

Authors:  Chao Zhu; Bin Wang; Jian Yin; Xin Hui Liu
Journal:  J Orthop Surg Res       Date:  2021-05-10       Impact factor: 2.359

6.  Enhancing percutaneous pedicle screw fixation with hydroxyapatite granules: A biomechanical study using an osteoporotic bone model.

Authors:  Haruo Kanno; Toshimi Aizawa; Ko Hashimoto; Eiji Itoi
Journal:  PLoS One       Date:  2019-09-26       Impact factor: 3.240

7.  Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO) System: A Cadaver Study.

Authors:  Guoxin Fan; Xiaofei Guan; Qi Sun; Annan Hu; Yanjie Zhu; Guangfei Gu; Hailong Zhang; Shisheng He
Journal:  PLoS One       Date:  2015-12-16       Impact factor: 3.240

8.  Accuracy of Percutaneous Pedicle Screw Insertion Technique with Conventional Dual Fluoroscopy Units and a Retrospective Comparative Study Based on Surgeon Experience.

Authors:  Masayuki Nakahara; Takao Yasuhara; Takafumi Inoue; Yuichi Takahashi; Shinji Kumamoto; Yasukazu Hijikata; Akira Kusumegi; Yushi Sakamoto; Koichi Ogawa; Kenki Nishida
Journal:  Global Spine J       Date:  2015-09-22

9.  Significant Improvement of Puncture Accuracy and Fluoroscopy Reduction in Percutaneous Transforaminal Endoscopic Discectomy With Novel Lumbar Location System: Preliminary Report of Prospective Hello Study.

Authors:  Guoxin Fan; Xiaofei Guan; Hailong Zhang; Xinbo Wu; Xin Gu; Guangfei Gu; Yunshan Fan; Shisheng He
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.