Literature DB >> 24076523

High sensitivity LC-MS/MS method for direct quantification of human parathyroid 1-34 (teriparatide) in human plasma.

Erin E Chambers1, Mary E Lame, Jon Bardsley, Sally Hannam, Cristina Legido-Quigley, Norman Smith, Kenneth J Fountain, Eileen Collins, Elizabeth Thomas.   

Abstract

Teriparatide, the 1-34 fragment of human parathyroid hormone, is used to treat osteoporosis patients with a high risk of fracture by stimulating new bone formation. Routinely teriparatide is quantified using radioimmunoassay however the LC-MS/MS described here has the potential to achieve greater accuracy and precision, higher specificity, and is readily implemented in routine bioanalytical laboratories. Hence a complete method combining effective sample prep with appropriate LC separation and selected reaction monitoring (SRM) MS detection was developed to selectively separate teriparatide from closely related endogenous peptides and to reduce interferences. Samples were concentrated without evaporation, minimizing the risk of adsorptive losses. Chromatography was performed on a sub 2μm particle charged surface hybrid column, which provided significantly higher peak capacity than a traditional C18 column when formic acid was used as the mobile phase modifier. Total LC cycle time was 6min. An LOD of 15pg/mL (3.6fmol/mL) from 200μL of human plasma was readily achieved and standard curves were accurate and precise from 15pg/mL to 500pg/mL. Mean QC accuracies ranged from 90% to 106%. Mean QC precision was better than 7%. The CV of matrix factors across 6 sources of human plasma was 5%. The assay presented here is the first LC-MS method which reaches clinically relevant detection limits for teriparatide.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bioanalysis; Human growth hormone; LC–MS/MS peptide quantification; Solid phase extraction (SPE); Teriparatide; rhPTH (1–34)

Mesh:

Substances:

Year:  2013        PMID: 24076523     DOI: 10.1016/j.jchromb.2013.08.027

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  2 in total

Review 1.  Application of liquid chromatography-tandem mass spectrometry in quantitative bioanalyses of organic molecules in aquatic environment and organisms.

Authors:  Ugo Bussy; Ke Li; Weiming Li
Journal:  Environ Sci Pollut Res Int       Date:  2016-03-21       Impact factor: 4.223

Review 2.  Peptide hormones and lipopeptides: from self-assembly to therapeutic applications.

Authors:  J A Hutchinson; S Burholt; I W Hamley
Journal:  J Pept Sci       Date:  2017-01-27       Impact factor: 1.905

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.