Literature DB >> 24075828

Comparison of the accuracy for three dental impression techniques and index: an in vitro study.

Erica Dorigatti de Avila1, Luiz Antonio Borelli Barros, Marcelo Antonialli Del'Acqua, Sabrina Maria Castanharo, Francisco de Assis Mollo.   

Abstract

OBJECTIVES: This in vitro study compared the dimensional accuracy of stone index (I) and three impression techniques: tapered impression copings (T), squared impression copings (S) and modified squared impression copings (MS) for implant-supported prostheses.
METHODS: A master cast, with four parallel implant abutment analogs and a passive framework, were fabricated. Vinyl polysiloxane impression material was used for all impressions with two metal stock trays (open and closed tray). Four groups (I, T, S and MS) were tested (n=5). A metallic framework was seated on each of the casts, one abutment screw was tightened, and the gap between the analog of implant and the framework was measured with a stereomicroscope. The groups' measurements (80 gap values) were analyzed using software (LeicaQWin - Leica Imaging Systems Ltd.) that received the images of a video camera coupled to a Leica stereomicroscope at 100× magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, 0.05.
RESULTS: The mean values of abutment/framework interface gaps were: Master Cast=32 μm (SD 2); Group I=45 μm (SD 3); Group T=78 μm (SD 25); Group S=134 μm (SD 30); Group MS=143 μm (SD 27). No significant difference was detected among Index and Master Cast (P=.05).
CONCLUSION: Under the limitations of this study, it could be suggested that a more accurate working cast is possible using tapered impression copings techniques and stone index.
Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dental implant; Impression material; Impression technique; Transfer coping

Mesh:

Substances:

Year:  2013        PMID: 24075828     DOI: 10.1016/j.jpor.2013.07.001

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  2 in total

1.  Comparing the Dimensional Accuracy of Casts Obtained from Two Types of Silicone Impression Materials in Different Impression Techniques and Frequent Times of Cast Preparation.

Authors:  Ali Hafezeqoran; Mahdi Rahbar; Roodabeh Koodaryan; Tina Molaei
Journal:  Int J Dent       Date:  2021-09-27

2.  Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Authors:  Rohini Rajendran; N Gopi Chander; Kuttae Vishwanathan Anitha; Balasubramanian Muthukumar
Journal:  Eur Oral Res       Date:  2021-05-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.