Literature DB >> 24075671

Assessment of the accuracy and reliability of new 3-dimensional scanning devices.

Kazuo Hayashi1, Arjun U C Sachdeva, Sadamasa Saitoh, Seung-Pyo Lee, Takao Kubota, Itaru Mizoguchi.   

Abstract

INTRODUCTION: The primary objective of this study was to assess the accuracy and the reliability of the SureSmile OraScanner (Orametrix, Richardson, Tex) by comparing it with other desktop 3-dimensional scanners: VIVID910 (Konica Minolta, Tokyo, Japan) and R700 (3Shape, Copenhagen, Denmark). A laser-based scanner, the SLP250 Laser Probe (Laser Design, Detroit, Mich), served as the gold standard.
METHODS: Five sets of dental casts were used. First, the accuracy of each scanner was studied by comparing the 3-dimensional models created by OraScanner, VIVID910, and R700 with the gold standard 3-dimensional models of the SLP250. To assess the reliability of the 3-dimensional models, the shell/shell deviation of each model was calculated based on the same surface-based registrations for all 5 sets of dental casts.
RESULTS: OraScanner, VIVID910, and R700 were sufficiently accurate when compared with the gold standard. In the assessment of reliability, there were no significant differences between all comparisons.
CONCLUSIONS: The results showed that the OraScanner system has a sophisticated algorithm for 3-dimensional surface registration and can be used to generate accurate and reliable 3-dimensional digital models for use by clinicians.
Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Mesh:

Year:  2013        PMID: 24075671     DOI: 10.1016/j.ajodo.2013.04.021

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  12 in total

1.  Assessing the accuracy of two posterior tooth-size discrepancy prediction methods based on virtual occlusal setups.

Authors:  Drew W Fallis
Journal:  Angle Orthod       Date:  2019-10-15       Impact factor: 2.079

2.  Palatal volume and area assessment on digital casts generated from cone-beam computed tomography scans.

Authors:  Shereef Shahen; Gennaro Carrino; Rossella Carrino; Reham Abdelsalam; Carlos Flores-Mir; Letizia Perillo
Journal:  Angle Orthod       Date:  2018-03-21       Impact factor: 2.079

3.  Comparison of the accuracy of intraoral digital impression system and conventional impression techniques for multiple implants in the full-arch edentulous mandible.

Authors:  Firas-Abdulameer Farhan; Ali-Jameel-Abdul Sahib; Abdalbseet-Ahmad Fatalla
Journal:  J Clin Exp Dent       Date:  2021-05-01

4.  Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions.

Authors:  Xin Yang; Pin Lv; Yihong Liu; Wenjie Si; Hailan Feng
Journal:  Materials (Basel)       Date:  2015-06-29       Impact factor: 3.623

5.  In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques.

Authors:  Emi Kamimura; Shinpei Tanaka; Masayuki Takaba; Keita Tachi; Kazuyoshi Baba
Journal:  PLoS One       Date:  2017-06-21       Impact factor: 3.240

6.  A comparison of the accuracy of intraoral scanners using an intraoral environment simulator.

Authors:  Hye-Nan Park; Young-Jun Lim; Won-Jin Yi; Jung-Suk Han; Seung-Pyo Lee
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

7.  Recommendations for clear aligner therapy using digital or plaster study casts.

Authors:  Hsiu-Ching Ko; Weitao Liu; Derek Hou; Sepideh Torkan; Charles Spiekerman; Greg J Huang
Journal:  Prog Orthod       Date:  2018-07-19       Impact factor: 2.750

8.  Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root.

Authors:  Seung-Weon Lim; Ryu-Jin Moon; Min-Seok Kim; Min-Hee Oh; Kyung-Min Lee; Hyeon-Shik Hwang; Tae-Woo Kim; Seung-Hak Baek; Jin-Hyoung Cho
Journal:  Korean J Orthod       Date:  2020-07-25       Impact factor: 1.372

9.  Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions.

Authors:  Tingting Jiang; Sang-Mi Lee; Yanan Hou; Xin Chang; Hyeon-Shik Hwang
Journal:  Korean J Orthod       Date:  2016-05-20       Impact factor: 1.372

10.  Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners.

Authors:  Leonardo T Camardella; Edwin M Ongkosuwito; E Willemijn Penning; Anne Marie Kuijpers-Jagtman; Oswaldo V Vilella; K Hero Breuning
Journal:  Korean J Orthod       Date:  2020-01-22       Impact factor: 1.372

View more