Beng Kwang Ng1, Pei Shan Lim, Mohamad Nasir Shafiee, Nur Azurah Abdul Ghani, Nor Azlin Mohamed Ismail, Mohd Hashim Omar, Muhammad Abdul Jamil Muhammad Yassin.
Abstract
Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart). Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6%) had ruptured membranes, while 24 patients (11.4%) had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (179 of 179), and negative predictive value of 75.0% (24 of 32). By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (146 of 146), and negative predictive value of 36.9% (24 of 65) in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning), the nitrazine test alone or fern test alone.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24073412 PMCID: PMC3773890 DOI: 10.1155/2013/587438
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Demographic data and clinical findings on admission.
| Total | |
|---|---|
| Age (years) | 28.0 (26.0, 28.0) |
| Ethnic | |
| Malay | 166 (78.7) |
| Chinese | 27 (12.8) |
| Indian | 12 (5.7) |
| Others | 6 (2.8) |
| Parity | 0 (0, 1) |
| Gestation age (weeks) at presentation | 38.3 (36.5, 39.3) |
| Gestational age <34 weeks | 19 (9.0) |
| History | |
| Duration of rupture membrane (hours) | 1.5 (1.0, 4.0) |
| Presence of contraction | 134 (63.5) |
| Presence of fever | 3 (1.4) |
| Presence of vaginal bleeding | 0 |
| Presence of vaginal discharge | 11 (5.2) |
| Examination | |
| Maternal tachycardia | 29 (13.7) |
| Abdominal tenderness | 1 (0.5) |
| Pooling of liquor | 162 (76.8) |
| Os dilatation (cm) | 2 (1, 3) |
All quantitative data were presented in median (quartile) unless specified.
Figure 1Summary of results for both standard diagnostic method and AmniSure.
Final determination of rupture of membrane and performance metrix of each test.
| Test | Result | Sensitivity (%) | Specificity (%) | Positive predictive value (%) | Negative predictive value (%) | |
|---|---|---|---|---|---|---|
| Positive | Negative | |||||
| Standard diagnostic methods | 146 | 41 | 78.1 | 100 | 100 | 36.9 |
| Placenta alpha microglobulin-1 | 179 | 8 | 95.7 | 100 | 100 | 75.0 |
| Nitrazine test | 145 | 42 | 77.5 | 100 | 100 | 36.3 |
| Fern test | 117 | 70 | 62.6 | 100 | 100 | 25.5 |
| Pooling of liquor | 162 | 25 | 86.6 | 100 | 100 | 49.0 |
Figure 2Positive AmniSure with negative standard diagnostic method in actual ROM.
Figure 3Negative AmniSure with positive standard diagnostic method in actual ROM.
Comparison to other trials.
| Study | Number of patients | Sensitivity (%) | Specificity (%) | Positive predictive value (%) | Negative predictive value (%) |
|---|---|---|---|---|---|
| Cousins et al. [ | 203 | 98.9 | 100 | 100 | 99.1 |
| Lee et al. [ | 184 | 98.7 | 87.5 | 98.1 | 91.3 |
| Our study | 211 | 95.7 | 100 | 100 | 75.0 |