| Literature DB >> 24068640 |
Hamid Javadi1, Sara Jallalat, Shahriar Semnani, Mehdi Mogharrabi, Iraj Nabipour, Seyed Masoud Tabib, Moloud Abbaszadeh, Majid Assadi.
Abstract
Myocardial perfusion imaging (MPI) is widely used in routine practice for diagnosis and risk stratification of coronary artery disease (CAD). Intense curvilinear activity in the stomach wall of a patient was seen on MPI raw data. This phenomenon was completely dissimilar to the familiar intraluminal gastric reflux of sestamibi. This observed activity could have resulted in false-positive or false-negative artifacts - and inaccurate diagnosis - of the inferior wall of the left ventricle after MPI processing. On further exploration, the current researchers found that the patient had a history of 10-year Omeprazole capsule consumption. The authors present this infrequent case of intense stomach uptake to stress the related clinical and diagnostic implications with the aim to stimulate acute awareness of possible, unexpected infringements on image quality that could potentially interfere with accurate interpretation of the data.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24068640 DOI: 10.5603/NMR.2013.0042
Source DB: PubMed Journal: Nucl Med Rev Cent East Eur ISSN: 1506-9680