OBJECTIVE: To describe and characterize local adverse effects (in the oral cavity, pharynx, and larynx) associated with the use of inhaled corticosteroids (ICSs) in patients with moderate or severe asthma. METHODS: This was a cross-sectional study involving a convenience sample of 200 asthma patients followed in the Department of Pharmaceutical Care of the Bahia State Asthma and Allergic Rhinitis Control Program Referral Center, located in the city of Salvador, Brazil. The patients were ≥ 18 years of age and had been using ICSs regularly for at least 6 months. Local adverse effects (irritation, pain, dry throat, throat clearing, hoarseness, reduced vocal intensity, loss of voice, sensation of thirst, cough during ICS use, altered sense of taste, and presence of oral candidiasis) were assessed using a 30-day recall questionnaire. RESULTS: Of the 200 patients studied, 159 (79.5%) were women. The mean age was 50.7 ± 14.4 years. In this sample, 55 patients (27.5%) were using high doses of ICS, with a median treatment duration of 38 months. Regarding the symptoms, 163 patients (81.5%) reported at least one adverse effect, and 131 (65.5%) had a daily perception of at least one symptom. Vocal and pharyngeal symptoms were identified in 57 (28.5%) and 154 (77.0%) of the patients, respectively. The most commonly reported adverse effects were dry throat, throat clearing, sensation of thirst, and hoarseness. CONCLUSIONS: Self-reported adverse effects related to ICS use were common among the asthma patients evaluated here.
OBJECTIVE: To describe and characterize local adverse effects (in the oral cavity, pharynx, and larynx) associated with the use of inhaled corticosteroids (ICSs) in patients with moderate or severe asthma. METHODS: This was a cross-sectional study involving a convenience sample of 200 asthmapatients followed in the Department of Pharmaceutical Care of the Bahia State Asthma and Allergic Rhinitis Control Program Referral Center, located in the city of Salvador, Brazil. The patients were ≥ 18 years of age and had been using ICSs regularly for at least 6 months. Local adverse effects (irritation, pain, dry throat, throat clearing, hoarseness, reduced vocal intensity, loss of voice, sensation of thirst, cough during ICS use, altered sense of taste, and presence of oral candidiasis) were assessed using a 30-day recall questionnaire. RESULTS: Of the 200 patients studied, 159 (79.5%) were women. The mean age was 50.7 ± 14.4 years. In this sample, 55 patients (27.5%) were using high doses of ICS, with a median treatment duration of 38 months. Regarding the symptoms, 163 patients (81.5%) reported at least one adverse effect, and 131 (65.5%) had a daily perception of at least one symptom. Vocal and pharyngeal symptoms were identified in 57 (28.5%) and 154 (77.0%) of the patients, respectively. The most commonly reported adverse effects were dry throat, throat clearing, sensation of thirst, and hoarseness. CONCLUSIONS: Self-reported adverse effects related to ICS use were common among the asthmapatients evaluated here.
Inhaled corticosteroids (ICSs) are currently the most effective therapeutic strategy
for asthma control and are recommended by national and international guidelines for
the management of the disease. Maintenance treatment with ICSs reduces asthma
symptoms, the frequency and severity of exacerbations, and the number of
hospitalizations, as well as improving the quality of life of patients.(
-
)Despite their efficacy, ICSs can cause local and systemic adverse
effects.(
-
) Their frequent use, for longer periods and in high doses, has been
accompanied by concerns about their potential adverse effects in the oral cavity and
pharynx, such as hoarseness, dysphonia, candidiasis, pharyngitis, and cough
reflex.(
,
,
)Approximately 5-10% of subjects treated with ICSs report adverse effects in the oral
cavity and pharynx, which are considered to be an immediate cause of clinical
discomfort, with poorer patient adherence to treatment and a consequent increase in
asthma morbidity.(
-
,
)Adverse effects resulting from the use of ICSs are underestimated by patients and
physicians and often are not identified in daily clinical practice.(
,
-
) In addition, information about the frequency and intensity with which
local adverse effects induced by ICSs strike patients is limited.(
) Patient reports about the adverse effects experienced are considered an
important source of information on adverse effects in pharmacovigilance and in
clinical practice.(
)The Programa para o Controle da Asma na Bahia (ProAR, Bahia State
Asthma Control Program) is a project involving care, education, and research and
aiming at ensuring concomitant control of asthma and allergic rhinitis by means of a
multidisciplinary approach including medical care, nursing care, psychological
follow-up, and pharmaceutical care.The objective of the present study was to describe and characterize local adverse
effects (in the oral cavity, pharynx, and larynx) associated with the use of ICSs in
patients with moderate or severe asthma and under treatment in the Department of
Pharmaceutical Care of the ProAR Referral Center.
Methods
The protocol for the treatment of ProAR patients includes non-pharmacological
measures, such as asthma self-management plans, psychological support, and an
education program for patients and their families, all of which are associated with
the Department of Pharmaceutical Care, which provides access to medications at no
cost and on a regular basis, including ICSs alone (budesonide, 200 µg; and
beclomethasone, 250 µg and 400 µg), a long-acting β2 agonist combined
with an ICS (formoterol + budesonide, 6/200 and 12/400 µg), and a short-acting
β2 agonist (fenoterol, 100 µg).The patients are followed monthly at the Department of Pharmaceutical Care, in which
the medications are dispensed and support is provided by means of strategic
interventions designed to promote the effectiveness and safety of the
pharmacological treatment, as well as adherence to it. These interventions include
assessment of the level of asthma control, systematic guidance on the proper
inhalation technique on a regular basis, intensive monitoring of adherence to
treatment, use of a spacer, and oral hygiene after ICS use.This cross-sectional descriptive study was conducted between June of 2009 and January
of 2010 and involved a convenience sample of 200 patients followed at the ProAR
Referral Center, located in the city of Salvador, Brazil.We included male and female subjects (≥ 18 years of age) who had been
diagnosed with moderate or severe persistent asthma,(
) were being regularly followed in the ProAR Department of Pharmaceutical
Care, and had been using ICSs regularly for at least 6 months.Patients who used oral, parenteral, ocular, or topic corticosteroids in the last
three months prior to the beginning of the study were not selected. A daily dose of
800 µg of beclomethasone was considered equivalent to a daily dose of 800 µg of
budesonide. Daily doses of 400-800 µg of budesonide were considered medium doses,
whereas daily doses above 800 µg of budesonide were considered high doses.The devices evaluated were classified into two groups: metered dose inhalers (MDIs),
with or without a spacer; and dry powder inhalers (DPIs), including Pulvinal®,
Aerolizer®, and Turbohaler®.All patients were evaluated by a pulmonologist and a pharmacist, both of whom had
been previously trained, after medical visits, in a room in the Department of
Pharmaceutical Care. The interview elicited information about the patient (gender
and age) and the characteristics of the ICS (formulation, daily dose, type of
inhaler, and duration of use), as well as about the practice of oral hygiene after
ICS use and about the use of nasal corticosteroids. The practice of oral hygiene was
considered correct when the patients rinsed their mouths with water immediately
after ICS use, gargled, and subsequently spat out the wash water.(
)Adverse effects were assessed using a 30-day recall questionnaire. The following
parameters were evaluated: throat conditions, such as irritation, pain, dryness, and
throat clearing; hoarseness; reduced vocal intensity and loss of voice; sensation of
thirst; cough during ICS use; altered sense of taste; and presence of oral
candidiasis. The frequency of adverse effects was classified into one of the
following categories: never; occasionally; on most days; or daily.The present study was approved by the Research Ethics Committee of the Federal
University of Bahia Climério de Oliveira Maternity Hospital. All patients gave
written informed consent, and their personal data were kept confidential.Data were analyzed with the Statistical Package for the Social Sciences, version 17.0
(SPSS Inc., Chicago, IL, USA). Simple descriptive frequency statistics was used to
determine the prevalence of each adverse effect and its degree of intensity. The
overall prevalence of adverse effects was estimated on the basis of the cases with
at least one adverse effect and the total number of asthmapatients evaluated. Means
and standard deviations were calculated for quantitative variables with normal
distribution. Categorical variables are expressed as proportions. The chi-square
test was used to assess the statistical significance between categorical variables,
and the Student's t-test was used to compare the means of quantitative data. The
level of statistical significance was set at p < 0.05 for all tests.
Results
We evaluated 200 patients, of whom 159 (79.5%) were female and 41 (20.5%) were male.
The mean age was 50.7 ± 14.4 years. In this sample, 55 patients (27.5%) were using
high doses of ICS (budesonide > 800 µg/day). The mean daily dose of ICS was 945 ±
345 µg, and 171 patients (85.5%) were found to be using budesonide. The duration of
treatment with ICSs was long, with the median being 38 months (range, 6-84
months).Of the sample as a whole, 153 (76.5%) reported performing oral hygiene after ICS use.
The general characteristics of the patients are shown in Table 1.
Table 1
General characteristics of the 200 patients with moderate or severe
asthma evaluated.a
In general, 95% of the patients used ICSs + long-acting β2 agonists
(formoterol + budesonide, in 85.5%; formoterol + budesonide and beclomethasone, in
14.5%) and only 5% used an ICS alone (beclomethasone, in 3.0%; and budesonide, in
2.0%). We found that 149 patients (74.5%) used only one inhaler and 51 (25.5%) used
two inhalers. Of the 200 patients, 162 (81.0%) used an Aerolizer® DPI, 45
(22.5%) used an MDI, 28 (14.0%) used a Turbohaler® DPI, and 17 (8.5%) used a
Pulvinal® DPI. Approximately two thirds of the patients (65%) used a nasal
corticosteroid (budesonide, in 91.5%, and beclomethasone, in 8.5%).Patient perception of adverse effects in the pharynx/larynx was found to be high
among the subjects with severe asthma, with at least one effect being observed in
81.5% of them, one to three effects being observed in 51.5%, and four to six effects
being observed in 23.5%.Of the patients evaluated, 58 (29.0%) perceived at least one vocal symptoms, with 37
(18.5%) reporting at least one voice-related adverse effect, 14 (7.0%) reporting two
adverse effects, and 7 (3.5%) reporting three adverse effects. The prevalence of
vocal symptoms found in the study was 26.0% for hoarseness and 11.5% for reduced
vocal intensity. The proportion of patients with the symptom of loss of voice was
found to be low (5.0%; Table 2).
Table 2
Frequency of adverse effects (in the oral cavity and pharynx)
reported by the 200 patients studied.a
Pharyngeal adverse effects induced by the use of ICSs were found to be the most prevalent. In 77% of the patients, there was at least one pharyngeal effect. The symptoms of dry throat and throat clearing were observed in 47% and
44% of the patients, respectively. Of the patients who reported adverse effects related to ICS use, 131 (65.5%) had a daily perception of symptoms, with the most commonly perceived effects being sensation of thirst, in 36 (18.0%); dry throat, in 33 (16.5%); and throat clearing, in 23 (11.5%).The frequencies of local symptoms reported by patients using medium and high doses of ICS are shown in Table 3. Although no statistically significant differences were identified between the two groups, the patients using high doses were more commonly affected by adverse effects than were those using medium doses (frequency of patients with one or more effects, 85.5% vs. 80.0%), as well as having reported a larger number of effects (mean number by patient, 2.76 effects vs. 2.52 effects). In addition, we observed that, for most of the adverse effects evaluated, prevalence increased as the daily dose of ICS was increased, especially for loss of voice (9.1% vs. 4.1%) and sore throat (14.5% vs. 6.9%).
Table 3
Frequency of local adverse effects in the patients studied, by use of medium- or high-dose inhaled corticosteroids.a
Although no statistically significant differences were identified between the groups
of patients with and without self-reported adverse effects for any of the
characteristics evaluated (Table 4), the
former group included older patients (mean age, 51.13 years vs. 48.59 years), as
well as higher proportions of females (80.9% vs. 73.0%), patients who used high
doses of ICS (28.8% vs. 21.6%), and patients who used a combination of two inhalers
(DPI + MDI; (20.2% vs. 13.5%).
Table 4
Comparison of general characteristics between patients with and
without at least one self-reported local adverse effect.a
Discussion
In the present study, patient perception of adverse effects in the oral cavity and
pharynx was found to be high among the subjects with moderate or severe asthma being
evaluated in clinical practice. Approximately 80% of the patients reported at least
one local adverse effect, which confirms the high prevalence of these effects. More
than half of the patients (65.5%) had a daily perception of at least one symptom.
The most prevalent symptoms were dry throat, need for throat clearing, and sensation
of thirst, the last being the most commonly reported adverse effect, affecting
approximately one quarter of the subjects daily.The high frequency of local adverse effects induced by ICSs found in the present
study is in agreement with the findings of various authors who used structured
questionnaires.(
-
,
,
) It is possible that our results are due to the fact that our sample
comprised patients with moderate or severe asthma who had been using medium or high
doses of ICS for extended periods of time, as well as to the fact that the adverse
effects experienced by the patients were assessed using a structured
questionnaire.The frequency of adverse effects in the oral cavity and pharynx varies widely.
Reviews on the subject describe symptoms that vary widely in frequency, such as
candidiasis (in 0-70% of patients), dysphonia (in 5-58%), and pharyngitis (in
4-25%).(
-
,
) This variation has been associated with differences in the study
designs, as well as in the length of the observation period and in the method of
collecting data on adverse effects, which usually involves using questionnaires or
clinical tests.(
,
) Although several clinical trials have estimated that these symptoms
affect 5-10% of the treated population, there is no scientific evidence from
real-life studies to support those findings.(
) However, some questionnaire-based studies have estimated the prevalence
of local adverse effects at 24-81%.(
,
) In the present study, the prevalence of symptoms in the oral cavity and
pharynx in asthmapatients is at the upper end of this range. The frequency of these
local effects can vary depending on the ICS dose and potency, as well as on the type
of inhaler used.(
,
,
,
,
)Pharyngeal symptoms affected more than half of the patients. The study revealed that
approximately half (47%) of the asthmapatients had the symptom of dry throat and
that 33 (16%) had a daily perception of this symptom. The high frequency and
intensity of this adverse effect was also observed in a recent study evaluating the
prevalence of potential adverse effects associated with the use of ICSs combined
with long-acting β 2 agonists in asthmapatients and COPDpatients.(
) The authors observed that the symptom of dry throat was reported by 52%
of the patients and that it was perceived, on average, 14 days per month. In
addition, a reduction in the total dose of ICS was responsible for a 47% reduction
in patient perception of this symptom, suggesting the dose-dependent nature of this
adverse effect.(
)A large proportion of patients (44%) reported the need for throat clearing, this
being the second most prevalent pharyngeal symptom. Throat clearing is a very common
adverse effect, affecting 24-65% of ICS users(
,
,
,
) and being more prevalent in patients using high daily doses. This local
adverse effect is defined as laryngitis caused by ICSs, which act by inducing a form
of chemical laryngopharyngitis, mimicking the clinical profile of laryngopharyngeal
reflux.(
)Sensation of thirst after ICS use was found in more than 40% of the subjects
evaluated in our study. This local symptom can correspond to a manifestation of oral
candidiasis or be caused by throat irritation.(
,
,
) In a cross-sectional questionnaire-based study, the prevalence of this
symptom ranged from 42% to 60% and was found to be dose-dependent.(
) In contrast, in another study, involving children with asthma and also
using a questionnaire, this symptom was present in 21.9% of ICS users, and
combination therapy with ICSs and long-acting β2 agonists was found to be
the only risk factor for the onset of this symptom.(
,
)The impact of ICSs on voice production has received considerable attention in recent
studies.(
-
,
,
,
) Vocal symptoms affect 39-83% of ICS users,(
,
,
,
,
) and the magnitude and extent of these symptoms have been found to be
dose-dependent.(
,
,
,
,
) In our study, we observed a lower frequency of vocal complaints than
that reported by other authors (28.5% in our study vs. 39-83% in other
studies).(
,
,
,
)Hoarseness was found to be most common vocal symptom reported by the patients (in
26%). In three questionnaire-based studies using methodologies similar to that used
in our study, the prevalence of hoarseness ranged from 10% to 57%.(
,
,
,
,
) According to a study, hoarseness is a local adverse effect dependent on
factors such as ICS formulation, type of inhaler, frequency of use, total daily
dose, ICS particle size, and local effect of the lactose contained in
DPIs.(
) The exact mechanism leading to hoarseness is unknown; however,
hoarseness can be attributed to steroidmyopathy affecting the vocal muscles, which
causes a bilateral adduction deformity and bowing of the vocal cords during
phonation.(
,
,
,
,
)Although the mechanisms by which ICSs cause local adverse effects have yet to be
clarified, they appear to be related to the deposition of the active ICS into the
oral cavity, pharynx, and larynx during drug administration.(
,
,
) Several factors can affect the fraction of an inhaled dose that is
deposited in the oral cavity. These factors include ICS formulation, type of drug
delivery system, and patient adherence to the instructions for use.(
)Our results showed no significant differences in the frequency of adverse events
between the groups being treated with moderate or high daily doses of ICS; however,
we observed an overall increase in the frequency of local effects, including vocal
symptoms, sore throat, and sensation of thirst, as the daily dose was increased.
According to one group of authors, high doses of ICS are associated with a higher
intensity and frequency of patient-perceived adverse events. (7)Although no significant differences were found in the general characteristics between
the patients who reported at least one adverse event and those who perceived no
adverse events, previous studies have demonstrated that the chronic use of ICSs,
usually in high doses, for long periods, and via different inhalers, is an important
risk factor for the incidence of adverse effects in the oral cavity and
pharynx.(
,
,
,
)One of the aspects that should be considered in the present study is the fact that
our sample of patients, who have moderate or severe asthma, participate in a
multidisciplinary outpatient care program in which there is good communication
between patients and health professionals, particularly regarding the cost-benefit
ratio of the treatment for asthma control. The good relationship between the health
care team and the patient makes it possible for the asthmapatients in our study to
discuss their symptoms and their concerns regarding the pharmacological treatment
more frequently, and this favors spontaneous reporting of adverse effects of
medications. According to one group of authors, open and honest communication with
patients, taking their concerns seriously, can reduce the impact caused by adverse
reactions to medications.(
) A previous qualitative study involving patients who reported suspected
reactions to paroxetine has suggested that understanding how the medication produced
the symptom can bring relief to the patient.(
,
)Assessment of the local adverse effects of ICSs, using a multidisciplinary approach
supported by a pharmaceutical care service, can be a useful tool in monitoring the
safety of use of these medications, since, in clinical practice, such effects tend
to be seen as "side effects" and, therefore, as deviations from the
priorities of patients and physicians.A previous study has demonstrated that asthmapatients prefer not to discuss their
concerns regarding ICS use with their physicians.(
) According to one group of authors, of 24% of patients who experienced
symptoms in the oral cavity and pharynx, only 16% reported their symptoms to their
physicians, and this might be associated with the existing communication gap between
patients and physicians.(
) In contrast, physicians tend not to discuss the potential adverse
effects associated with the use of the prescribed medications with their
patients.(
,
) Good safety monitoring encourages health professionals to take full
responsibility for the medications they prescribe, improving clinical effectiveness
and increasing the confidence with which they and their patients use these
medications.(
)With regard to the local symptoms (in the oral cavity, pharynx, and larynx)
associated with the use of ICSs, as well as to management recommendations and
preventive measures, the educational approach provided by the ProAR Department of
Pharmaceutical Care appears not to be sufficient for ensuring a lesser impact of
these symptoms, although it favors an improvement in patient perception of local
adverse effects. A study conducted in Canada showed that, although some
recommendations for the management of symptoms in the oral cavity and pharynx made
by family physicians are logical, they can be insufficient in some
situations.(
) In the present study, we observed that more than 70% of the patients
reported performing oral hygiene after ICS use. Although the practice of oral
hygiene after ICS use is an important measure to remove ICSs from the oral cavity,
this measure is ineffective in cleaning the larynx.(
) Previous studies have demonstrated that rinsing the mouth after ICS use
reduces the incidence of candidiasis; however, this does not have an impact on voice
or throat symptoms.(
,
,
,
)Although the questionnaire used in the present study was designed to assess the
occurrence of local symptoms associated with the use of ICSs, we cannot absolutely
rule out the possibility that, for some patients, these symptoms were related to
other alternative causes, such as comorbidities and continuous use of other
medications.The study design allowed us to control the use of systemic corticosteroids in the
three months preceding the study; however, we could not control their use beyond
this point. In addition, it was not possible to control the use of nasal
corticosteroids, the use of which was identified in more than half of the patients
evaluated. Nasal corticosteroids can penetrate the pharynx and larynx, and,
consequently, they have the potential to cause symptoms in the oral cavity and
pharynx.In conclusion, patient perception of local adverse effects associated with the use of
ICSs, especially pharyngeal symptoms, including dry mouth and need for throat
clearing, is high among the asthmapatients followed in the ProAR Department of
Pharmaceutical Care. This high frequency of local symptoms might be associated with
the use of medium and high doses of ICS, as well as with long-term exposure to ICSs.
Assessment of asthmapatient perception of local adverse effects of ICSs could
provide a greater understanding of the extent and severity of these effects and
could aid in determining the risk-benefit ratio of the use of ICSs in clinical
practice. Although ICSs are highly effective in the treatment of asthma, their
rational use, on the basis of a step-down therapeutic approach, must be ensured in
order to reach the lowest maintenance dose consistent with the best level of disease
control.
Introdução
Os corticosteroides inalatórios (CIs) representam atualmente a estratégia
terapêutica mais efetiva para o controle da asma e são preconizados por
diretrizes nacionais e internacionais para o manejo da doença. O tratamento de
manutenção com os CIs reduz os sintomas da asma, a frequência e a gravidade das
exacerbações e o número de hospitalizações, assim como melhora a qualidade de
vida dos pacientes.(
-
)A despeito de sua eficácia, os CIs podem gerar eventos adversos locais e
sistêmicos.(
-
) Seu uso frequente, por períodos mais longos e em doses elevadas,
tem sido acompanhado da preocupação acerca de seus potenciais eventos adversos
na orofaringe, tais como rouquidão, disfonia, candidíase, faringite e reflexo de
tosse.(
,
,
)Cerca de 5-10% dos indivíduos tratados com CI referem eventos adversos na
orofaringe, os quais são apontados como uma causa imediata de desconforto
clínico, com redução da adesão do paciente ao tratamento e consequente elevação
da morbidade da asma.(
-
,
)Os eventos adversos decorrentes do uso de CIs são subestimados por pacientes e
médicos e frequentemente não são identificados na prática clínica
diária.(
,
-
) Adicionalmente, as informações sobre a frequência e a intensidade
com que os eventos adversos locais induzidos por CI impactam sobre os pacientes
são limitadas.(
) O relato do paciente acerca dos eventos adversos experimentados é
considerado uma fonte de informação importante sobre eventos adversos na
farmacovigilância e na prática clínica.(
)O Programa para o Controle da Asma na Bahia (ProAR) é um projeto de assistência,
ensino e pesquisa que visa garantir o controle integrado da asma e da rinite
alérgica, por meio de uma abordagem multidisciplinar que inclui assistência
médica, assistência de enfermagem, acompanhamento psicológico e assistência
farmacêutica.O presente estudo teve como objetivo descrever e caracterizar os eventos adversos
locais na orofaringe e laringe associados ao uso de CIs em pacientes com asma
moderada ou grave atendidos no Serviço de Assistência Farmacêutica da central de
referência do ProAR.
Métodos
O protocolo de atendimento dos pacientes do ProAR inclui medidas não
medicamentosas, tais como planos de automanejo da asma, suporte psicológico e
programa de educação para pacientes e familiares, associados ao Serviço de
Assistência Farmacêutica, que oferece acesso gratuito e regular a medicamentos,
incluindo CI isolado (budesonida, 200 µg; e beclometasona, nas apresentações de
250 µg ou 400 µg); combinação de β2-agonista de longa ação e CI (formoterol +
budesonida, nas apresentações 6/200 µg e 12/400 µg); e β2-agonista de curta
ação (fenoterol, 100 µg).Os pacientes são acompanhados mensalmente em consultas farmacêuticas, nas quais
são realizadas a dispensação orientada dos medicamentos, com a implantação de
ações estratégicas de fomento da efetividade, segurança e adesão ao tratamento
medicamentoso. Tais ações incluem a avaliação do nível de controle da asma, a
orientação sistemática e regular da técnica inalatória correta, a monitorização
intensiva da adesão ao tratamento e a verificação do uso do espaçador e da
higiene bucal pós-inalação.O presente estudo transversal e descritivo foi realizado entre os meses de junho
de 2009 e janeiro de 2010 com uma amostra de conveniência composta por 200
pacientes acompanhados no centro de referência do ProAR, em Salvador (BA).Participaram do estudo indivíduos de ambos os sexos, com idade ≥ 18 anos, com
diagnóstico de asma persistente moderada ou grave,(
) acompanhados regularmente no Serviço de Assistência Farmacêutica do
ProAR, e que estavam em uso regular de CI por um período maior ou igual a seis
meses.Não foram selecionados pacientes que utilizaram corticosteroides orais,
parenterais, oculares ou tópicos nos últimos três meses que antecederam o início
do estudo. A beclometasona na dose diária de 800 µg foi equivalente a 800 µg de
budesonida. Foram consideradas como doses médias as doses diárias de 400-800 µg
de budesonida, enquanto foram consideradas como doses altas aquelas acima de 800
µg de budesonida/dia.(
)Os dispositivos avaliados foram classificados em dois grupos: inalador
dosimetrado (ID), de forma isolada ou com o uso de espaçador, e o grupo de
inaladores de pó seco (IPS), que incluíam os dispositivos
PulvinalÂ(r), AerolizerÂ(r) e
TurbohalerÂ(r).Todos os pacientes foram avaliados por um pneumologista e um farmacêutico, ambos
previamente treinados, na sala de pós-consulta do Serviço de Assistência
Farmacêutica. Durante a entrevista, foram coletadas informações do paciente
(sexo e idade) e aquelas relacionadas às características do CI (medicamento,
dose diária, tipo de dispositivo inalatório e tempo de uso), assim como em
relação à prática de higiene bucal após a inalação e ao uso de corticosteroide
nasal. A prática de higiene oral foi considerada correta quando o paciente
enxaguava a cavidade bucal com água imediatamente após a inalação do CI,
gargarejava e, em seguida, cuspia a água de lavagem.(
)A avaliação dos eventos adversos foi realizada por meio de um questionário
estruturado com um período recordatório de 30 dias. Foram avaliados os seguintes
sintomas: irritação, dor, secura e pigarro na garganta; rouquidão; redução da
potência e perda de voz; sensação de sede; tosse durante inalação; alteração do
paladar; e a presença de monilíase oral. A frequência dos eventos adversos foi
classificada em uma das seguintes categorias: nunca, ocasionalmente, na maioria
dos dias ou diariamente.O presente estudo foi aprovado pelo Comitê de Ética em Pesquisa da Maternidade
Climério de Oliveira da Universidade Federal da Bahia. Todos os pacientes
assinaram o termo de consentimento livre e esclarecido, e seus dados de
identificação foram mantidos em confidencialidade.Os dados foram analisados através do programa Statistical Package for the
Social Sciences, versão 17,0 (SPSS Inc., Chicago, IL, EUA). A
estatística descritiva de frequência simples foi utilizada para determinar a
prevalência de cada evento adverso e de sua categoria de intensidade. A
prevalência geral de eventos foi estimada com base nos casos de relato de pelo
menos um evento adverso e no número total de asmáticos avaliados. A média e o
desvio-padrão foram calculados para as variáveis quantitativas que apresentaram
distribuição normal. As variáveis categóricas foram apresentadas em forma de
proporções. O teste do qui-quadrado foi utilizado para a avaliação de
significância estatística entre variáveis categóricas, e o teste t de Student
foi utilizado para a comparação entre as médias dos dados quantitativos. O nível
de significância estatística adotado foi de p < 0,05 para todos os
testes.
Resultados
Foram avaliados 200 pacientes, dos quais 159 (79,5%) eram do gênero feminino, e
41 (20,5%), do gênero masculino, com média de idade de 50,7 ± 14,4 anos. Nessa
amostra, 55 pacientes (27,5%) utilizavam altas doses de CI (budesonida > 800
µg/dia). A média de dose diária de CI foi de 945 ± 345 µg, sendo que o uso de
budesonida foi identificado em 171 pacientes (85,5%). A duração do tempo de
tratamento com CI foi elevada, com mediana de 38 meses (variação, 6-84
meses).Do total de pacientes, 153 (76,5%) relataram fazer a higiene bucal pós-inalação.
As características gerais dos pacientes são apresentadas na Tabela 1.
Tabela 1
Características gerais dos 200 pacientes com asma moderada ou
grave avaliados.a
De forma geral, 95% dos pacientes utilizavam CIs + β2-agonista de
longa ação (formoterol + budesonida, em 85,5%; formoterol + budesonida e
beclometasona, em 14,5%) e somente 5% utilizavam CI isolado (beclometasona, em
3,0%; e budesonida, em 2,0%). Quanto ao uso dos dispositivos inalatórios, 149
pacientes (74,5%) utilizavam apenas um dispositivo inalatório, e 51 (25,5%),
dois dispositivos. Dos 200 pacientes, 162 (81,0%) utilizavam o IPS
AerolizerÂ(r), 45 (22,5%) utilizavam ID, 28 (14,0%) utilizavam o
IPS TurbohalerÂ(r), e 17 (8,5%) utilizavam o IPS
PulvinalÂ(r). Aproximadamente dois terços dos pacientes (65%)
utilizavamcorticosteroide nasal (budesonida, em 91,5%; e beclometasona, em
8,5%).Observou-se que os asmáticos graves avaliados apresentaram uma elevada percepção
de eventos adversos na laringofaringe, sendo observado pelo menos um evento, em
81,5% dos pacientes; de um a três eventos, em 51,5%; e de quatro a seis eventos,
em 23,5%.Dos pacientes avaliados, 58 (29,0%) tiveram a percepção de pelo menos um sintoma
de voz, sendo que 37 (18,5%) relataram pelo menos um evento adverso relacionado
à voz, 14 (7,0%) relataram dois eventos adversos, e 7 (3,5%) relataram três
eventos adversos. A prevalência dos sintomas de voz encontrada no estudo foi de
26,0% para rouquidão e 11,5% para dificuldade de falar alto. Notou-se uma baixa
proporção de pacientes (5,0%) afetados com o sintoma de perda de voz (Tabela 2).
Tabela 2
Frequência de eventos adversos de orofaringe relatados pelos 200
pacientes estudados.a
Os eventos adversos faríngeos induzidos pelo uso de CI apresentaram-se como os
mais prevalentes. Em 77% dos pacientes, houve pelo menos um evento faríngeo.
Sintomas de garganta seca e pigarro na garganta foram observados em 47% e 44%
dos pacientes, respectivamente. Dos pacientes que relataram eventos adversos
relacionados ao uso de CI, 131 (65,5%) tinham a percepção diária dos sintomas,
sendo que os eventos mais intensamente percebidos foram sensação de sede, em 36
(18,0%); garganta seca, em 33 (16,5%); e pigarro na garganta, em 23 (11,5%).As frequências de sintomas locais relatados por pacientes utilizando doses médias
e elevadas de CI são apresentadas na Tabela
3. Embora nenhuma diferença estatisticamente significante tenha sido
identificada entre os grupos, os pacientes em uso de doses altas foram mais
afetados por eventos adversos locais (frequência de pacientes com um ou mais
eventos, 85,5% vs. 80,0%) e relataram um maior número de eventos (número médio
por paciente, 2,76 eventos vs. 2,52 eventos). Adicionalmente, para a maioria dos
eventos adversos locais avaliados, observou-se um aumento de sua prevalência com
o aumento da dose diária de CI, principalmente em relação à perda de voz (9,1%
vs. 4,1%) e garganta dolorida (14,5% vs. 6,9%).
Tabela 3
Frequência de eventos adversos locais nos pacientes estudados em
relação ao uso de corticosteroide inalatório em doses médias ou
altas.a
Em nenhuma das características avaliadas foi identificada uma diferença
significante entre os grupos de pacientes com e sem percepção de evento adverso
(Tabela 4); contudo, os pacientes
com percepção de eventos eram mais velhos (média de idade, 51,13 anos vs. 48,59
anos), do gênero feminino (80,9% vs. 73,0%), faziam uso de altas doses de CI
(28,8% vs. 21,6%) e utilizavam a combinação IPS + ID (20,2% vs. 13,5%).
Tabela 4
Comparação de características gerais entre os pacientes com e
sem a percepção de pelo menos um evento adverso local.a
Discussão
No presente estudo, foi observada uma elevada percepção de eventos adversos de
orofaringe em pacientes com asma moderada ou grave avaliados na prática clínica.
Aproximadamente 80% dos pacientes relataram pelo menos um evento adverso local,
o que confirma sua alta prevalência. Mais da metade dos pacientes (65,5%) tinha
a percepção diária de pelo menos um sintoma. Os sintomas mais prevalentes foram
garganta seca, necessidade de pigarrear e sensação de sede, sendo esse último o
evento mais frequentemente relatado pelos pacientes, afetando diariamente cerca
de um quarto dos indivíduos.A elevada frequência de eventos adversos locais induzidos pelos CIs observada no
presente trabalho é corroborada por vários autores que utilizaram questionários
estruturados.(
-
,
,
) Esses resultados podem dever-se ao fato de nossa amostra ser
composta por pacientes com asma moderada ou grave, em uso de doses médias ou
altas de CI por períodos prolongados, assim como ao fato de ter sido realizado
um inquérito dos eventos adversos experimentados pelos pacientes por meio de um
questionário estruturado.A frequência dos eventos adversos de orofaringe varia amplamente. Revisões sobre
o tema descrevem sintomas com ampla variação, tais como candidíase (0-70% dos
pacientes), disfonia (5-58%) e faringite (4-25%).(3-5,12) Essa
variação tem sido associada às diferenças nos delineamentos dos estudos, assim
como no tempo/período de observação e no método de coleta dos eventos adversos,
que geralmente é realizada por meio de questionários ou exames
clínicos.(
,
) Apesar de diversos ensaios clínicos estimarem que tais sintomas
afetem 5-10% da população tratada, não há evidências científicas a partir de
estudos na vida real que corroborem esses achados.(
) Entretanto, alguns estudos baseados em questionários estimam a
prevalência de eventos adversos locais de 24-81%.(
,
) No presente estudo, a prevalência dos sintomas de orofaringe em
asmáticos está no extremo superior dessa faixa. A frequência desses eventos
locais pode variar de acordo com a dose e a potência do CI, assim como com o
tipo de dispositivo inalatório utilizado.(
,
,
,
,
)Os sintomas faríngeos afetaram mais da metade dos pacientes. O estudo revelou que
cerca de metade (47%) dos asmáticos apresentava garganta seca, sendo que, em 33
(16%), havia a percepção diária desse sintoma. A elevada frequência e
intensidade desse evento foi também observada em um estudo recente que avaliou a
prevalência de potenciais eventos adversos associados ao uso da combinação de CI
+ β2-agonista de longa ação em asmáticos e portadores de
DPOC.(
) Os autores observaram que o sintoma de garganta seca foi relatado
por 52% dos pacientes, sendo percebido, em média, 14 dias por mês.
Adicionalmente, a redução na dose total de CI foi responsável pela redução de
47% na percepção desse sintoma, sugerindo a natureza dose-dependente desse
evento.(
)Uma grande parte dos pacientes (44%) reportou a necessidade de pigarrear, sendo
esse o segundo sintoma faríngeo mais prevalente. O pigarro na garganta é um
evento adverso bastante frequente, que acomete 24-65% dos usuários de
CI,(
,
,
,
) sendo mais prevalente em pacientes em uso de altas doses diárias.
Esse evento local é definido como uma laringite causada por CI, que age
induzindo uma laringofaringite química, mimetizando um quadro clínico de refluxo
laringofaríngeo.(
)A sensação de sede após o uso de CI foi encontrada em mais de 40% dos indivíduos
avaliados em nosso estudo. Esse sintoma local pode corresponder a uma
manifestação de candidíase oral ou pode ser causada por irritação na
garganta.(
,
,
) Em um estudo de corte transversal baseado em questionário, a
prevalência desse sintoma variou de 42-60% e mostrou-se
dose-dependente.(
) Já em outro estudo envolvendo crianças asmáticas, também utilizando
um questionário, esse sintoma esteve presente em 21,9% dos usuários de CI, e o
uso da terapia combinada de CI e β2-agonista de longa ação
apresentou-se como o único fator de risco para seu surgimento.(
,
)O impacto dos CIs sobre a produção de voz tem recebido uma considerável atenção
em trabalhos recentes.(
-
,
,
,
) Os sintomas de voz afetam 39-83% dos usuários de CI,(
,
,
,
,
) sendo que sua magnitude e extensão mostram-se
dose-dependente.(6,7,15,16,18). Em nosso estudo, observamos uma
frequência de queixas relacionadas à voz inferior à observada por outros autores
(28,5% em nosso estudo vs. 39-83% em outros estudos).(
,
,
,
)Verificamos que a rouquidão foi o sintoma de voz mais frequentemente relatado
pelos pacientes, em 26%. Em três estudos baseados em questionários que
utilizaram metodologias semelhantes à empregada em nosso protocolo, a
prevalência de rouquidão variou de 10-57%.(
,
,
,
,
) Segundo um estudo, a rouquidão é um evento adverso local dependente
de fatores, tais como CI utilizado, tipo de dispositivo inalatório, frequência
de uso, dose diária total, tamanho da partícula do CI e efeito local da lactose
presente nos IPS.(18) O mecanismo exato da rouquidão é desconhecido;
contudo, essa pode ser atribuída à miopatia esteroide que afeta os músculos
vocais, gerando uma deformidade adutora bilateral e o encurvamento das pregas na
fonação.(
,
,
,
,
)Embora os mecanismos pelos quais os CIs causam eventos adversos locais não
estejam bem claros, esses parecem estar relacionados à deposição do CI ativo na
orofaringe e na laringe durante a administração do medicamento, que pode chegar
a 80% da dose administrada.(
,
,
) Diversos fatores podem influenciar a proporção de uma dose inalada
que é depositada na cavidade orofaríngea. Esses incluem a formulação do CI, o
tipo de sistema de liberação do medicamento e a adesão do paciente às instruções
para sua administração.(
)Nossos resultados não mostraram diferenças significantes em relação à frequência
de eventos adversos nos grupos com doses diárias de CI moderadas e elevadas;
entretanto, foi observado um aumento global da frequência de eventos locais,
incluindo sintomas de voz, garganta dolorida e sensação de sede, com o aumento
da dose. Segundo um grupo de autores, altas doses de CI estão associadas com
maior intensidade e frequência de efeitos adversos percebidos pelos
pacientes.(7)Embora nenhuma diferença tenha sido encontrada em relação às características
gerais dos pacientes que relataram pelo menos um evento adverso com aqueles sem
a percepção de eventos adversos, estudos anteriores têm demonstrado que o uso
crônico de CI, geralmente em altas doses, por períodos longos e em combinação
com diferentes dispositivos inalatórios, são fatores de risco importantes para a
incidência de eventos adversos em orofaringe.(
,
,
,
)Uma das considerações a serem feitas no presente estudo é que nossa amostra de
pacientes, com asma moderada ou grave, participa de um programa
multiprofissional de atendimento ambulatorial, no qual há uma boa comunicação
entre os pacientes e os profissionais de saúde, principalmente no que diz
respeito à relação risco-benefício do tratamento de controle da asma. A boa
relação entre a equipe de saúde e o paciente faz com que os asmáticos do nosso
estudo discutam mais frequentemente seus sintomas e preocupações associadas à
terapia medicamentosa, o que acaba favorecendo a notificação espontânea de
eventos adversos a medicamentos. De acordo com um grupo de autores, uma
comunicação aberta e honesta com os pacientes, que leve a sério suas
preocupações, poderá melhorar o impacto causado por uma reação adversa a
medicamentos.(
) Um estudo qualitativo prévio com pacientes que reportaram suspeitas
de reações à paroxetina tem sugerido que o entendimento de como o medicamento
propiciou o sintoma pode trazer alívio para o paciente.(
,
)A avaliação dos eventos adversos locais dos CIs, utilizando um enfoque
multiprofissional e alicerçado por um serviço de assistência farmacêutica, pode
ser uma alternativa útil na monitorização da segurança do uso desses
medicamentos, já que, na prática clínica, tais eventos tendem a ser vistos como
"efeitos colaterais" e, sendo assim, como desvios das prioridades de
pacientes e médicos.Um estudo prévio demonstrou que pacientes com asma preferem não discutir com seus
médicos suas preocupações associadas ao uso dos CIs.(13) De acordo
com um grupo de autores, de 24% dos pacientes que apresentaram sintomas de
orofaringe, apenas 16% reportaram seus sintomas ao médico, e isso pode estar
associado à lacuna existente na comunicação entre pacientes e médicos.(12)
Por outro lado, os médicos tendem a não discutir com seus pacientes os
potenciais eventos adversos associados ao uso dos medicamentos
prescritos.(
,
) A boa monitorização da segurança encoraja os profissionais da saúde
a assumir uma responsabilidade mais completa pelos medicamentos que prescrevem,
melhorando a efetividade clínica e aumentando a confiança com que eles e seus
pacientes utilizam esses medicamentos.(
)A abordagem educativa fornecida pelo Serviço de Assistência Farmacêutica do
ProAR, no que diz respeito aos sintomas de orofaringe e laringe associados aos
CIs, bem como às suas recomendações de manejo e medidas de prevenção, apesar de
favorecer uma maior percepção dos eventos adversos locais por parte dos
pacientes, parece não ser suficiente para garantir um menor impacto dos sintomas
locais. Um estudo no Canadá mostrou que, embora algumas ações de recomendações
feitas pelos médicos de família para o manejo dos sintomas de orofaringe sejam
lógicas, em algumas situações elas podem ser insuficientes.(
) No presente estudo, observamos que mais de 70% dos pacientes
relataram realizar a higiene bucal pós-inalação. A prática de higiene oral
pós-inalação representa uma medida importante para a remoção dos CIs da cavidade
bucal; entretanto, essa medida é pouco efetiva para a limpeza da
laringe.(
) Estudos prévios demonstram que lavar a boca após a inalação do CI
reduz a incidência de candidíase; contudo, isso não produz um impacto sobre os
sintomas de voz e garganta.(
,
,
,
)Embora o questionário aplicado no presente estudo tenha sido desenhado para
explorar a ocorrência de sintomas locais associados ao uso de CI, não podemos
excluir absolutamente a possibilidade de que, para alguns pacientes, tais
sintomas tenham sido relacionados a outras causas alternativas, como
comorbidades e uso contínuo de outros medicamentos.O desenho do estudo nos permitiu controlar o uso do corticosteroides sistêmicos
nos três meses anteriores a pesquisa; contudo, não pudemos controlar seu uso
além desse ponto. Adicionalmente, não foi possível controlar o uso de
corticosteroides nasais, cujo uso foi identificado em mais da metade dos
pacientes avaliados. O corticosteroide nasal pode penetrar na laringofaringe e,
consequentemente, tem o potencial de gerar sintomas de orofaringe.Em conclusão, os asmáticos acompanhados no Serviço de Assistência Farmacêutica do
ProAR possuem uma elevada percepção de eventos adversos locais associados ao uso
dos CIs, com destaque para os sintomas faríngeos, incluindo boca seca e
necessidade de pigarrear. Essa alta frequência de sintomas locais pode estar
associada ao uso de doses médias e altas de CI, assim como ao longo período de
exposição aos CIs. A avaliação da percepção dos eventos adversos locais dos CIs
na perspectiva do paciente asmático poderá fornecer um maior entendimento acerca
da extensão e severidade desses eventos, assim como auxiliar no julgamento da
relação risco-benefício do uso de CIs na prática clínica. Apesar da elevada
efetividade dos CIs no tratamento da asma, seu uso racional, baseado em uma
abordagem terapêutica descendente (step-down), deve ser
assegurado com o intuito de se alcançar a menor dose de manutenção compatível
com o melhor nível de controle da doença.
Authors: Mathieu Molimard; Vincent Le Gros; Philip Robinson; Isabelle Bourdeix Journal: J Aerosol Med Pulm Drug Deliv Date: 2010-04 Impact factor: 2.849
Authors: Elham Hossny; Nelson Rosario; Bee Wah Lee; Meenu Singh; Dalia El-Ghoneimy; Jian Yi Soh; Peter Le Souef Journal: World Allergy Organ J Date: 2016-08-12 Impact factor: 4.084
Authors: Simon Wan Yau Ming; John Haughney; Dermot Ryan; Shishir Patel; Matthias Ochel; Martina Stagno d'Alcontres; Susannah Thornhill; Janwillem W H Kocks; David Price Journal: NPJ Prim Care Respir Med Date: 2019-02-08 Impact factor: 2.871