| Literature DB >> 24067568 |
Ryan A Skilton1, Andrew J Parrott, Michael W George, Martyn Poliakoff, Richard A Bourne.
Abstract
The use of automated continuous flow reactors is described, with real-time online Fourier transform infrared spectroscopy (FT-IR) analysis to enable rapid optimization of reaction yield using a self-optimizing feedback algorithm. This technique has been applied to the solvent-free methylation of 1-pentanol with dimethyl carbonate using a γ-alumina catalyst. Calibration of the FT-IR signal was performed using gas chromatography to enable quantification of yield over a wide variety of flow rates and temperatures. The use of FT-IR as a real-time analytical technique resulted in an order of magnitude reduction in the time and materials required compared to previous studies. This permitted a wide exploration of the parameter space to provide process understanding and validation of the optimization algorithms.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24067568 DOI: 10.1366/13-06999
Source DB: PubMed Journal: Appl Spectrosc ISSN: 0003-7028 Impact factor: 2.388