Literature DB >> 24066919

Effects of pneumoperitoneum induced at various pressures on cardiorespiratory function and working space during laparoscopy in cats.

Philipp D Mayhew1, Peter J Pascoe, Philip H Kass, Yael Shilo-Benjamini.   

Abstract

OBJECTIVE: To evaluate the effect of pneumoperitoneum on cardiorespiratory variables and working space during experimental induction of 3 intra-abdominal pressures (IAPs) in cats. ANIMALS: 6 healthy young adult neutered male domestic shorthair cats. PROCEDURES: All cats were anesthetized through use of a standardized protocol. A catheter was placed in the right femoral artery for blood pressure and blood gas monitoring. A thermodilution catheter was placed in the right jugular vein via fluoroscopic guidance. Cardiopulmonary variables were measured before (baseline) and 2 and 30 minutes after initiation of pneumoperitoneum at IAPs of 4, 8, and 15 mm Hg; these were created through the use of a mechanical insufflator. At each IAP, abdominal dimensions (height, width, and circumference) were measured at a standardized location.
RESULTS: At 4 mm Hg and 8 mm Hg IAP, no clinically important changes were identified in cardiorespiratory values. Heart rate, cardiac index, and stroke volume index remained unchanged throughout the study at all IAPs. Mean arterial blood pressure began to increase at 8 mm Hg and was significantly higher, compared with baseline, at both time points at 15 mm Hg. At 15 mm Hg, Paco2 was significantly higher and cats were more acidotic than at baseline. Working space was subjectively greater at 8 mm Hg than at 4 mm Hg IAP; however, at 15 mm Hg, no clinically important enlargement of the working space was identified, compared with at 8 mm Hg. CONCLUSIONS AND CLINICAL RELEVANCE: Values of cardiopulmonary variables were largely unchanged by induction of pneumoperitoneum in healthy cats up to an IAP of 8 mm Hg, and no clinically important increases in working space were evident at an IAP of 15 versus 8 mm Hg. These findings provide little justification for use of IAPs > 8 mm Hg in healthy cats undergoing laparoscopic procedures; however, whether the situation is similar in diseased or elderly cats remains to be determined.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24066919     DOI: 10.2460/ajvr.74.10.1340

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  4 in total

1.  Cardiovascular and respiratory effects of carbon dioxide pneumoperitoneum in the domestic rabbit (Oryctolagus cuniculus).

Authors:  Claudia Kabakchiev; Alexander Valverde; Ameet Singh; Hugues Beaufrère
Journal:  Can J Vet Res       Date:  2020-04       Impact factor: 1.310

2.  Laparoscopic versus Open Ovariectomy in Bitches: Changes in Cardiorespiratory Values, Blood Parameters, and Sevoflurane Requirements Associated with the Surgical Technique.

Authors:  Silvia Fernández-Martín; Victoria Valiño-Cultelli; Antonio González-Cantalapiedra
Journal:  Animals (Basel)       Date:  2022-06-02       Impact factor: 3.231

3.  Abdominal wall-lifting versus CO2 pneumoperitoneum in laparoscopy: a review and meta-analysis.

Authors:  Hao Ren; Yao Tong; Xi-Bing Ding; Xin Wang; Shu-Qing Jin; Xiao-Yin Niu; Xiang Zhao; Quan Li
Journal:  Int J Clin Exp Med       Date:  2014-06-15

4.  A Modern Approach to Minimally Invasive Surgery and Laparoscopic Sterilization in a Chimpanzee.

Authors:  Laura K Newcomb; Meghan A Kruse; Larry J Minter; Craig J Sobolewski
Journal:  Case Rep Vet Med       Date:  2019-09-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.