Mandibular fractures through endosseous cylinder implants: report of cases and review.

M E Mason1, R G Triplett, J E Van Sickels, S M Parel.   

Abstract

These case reports and review focus on three mandibular fractures that occurred through endosseous cylinder implant sites. The first patient, and most likely the second, had osteoporotic changes that affected their already atrophic mandibles. The third patient probably had an area of deficient mineralization or poorly consolidated bone in the region where the fracture developed. These bony conditions increased the potential for fracture. Although the exact mechanism by which such fractures occur is not known, an examination of past research suggests that stress concentration at the mandibular defect prepared for implant placement is a probable explanation. The site of an implant that has not yet osseointegrated acts as a site of tensile stress concentration and ultimately an area of weakness. Consequently, this area of weakness in a mandible with decreased bone density or mineralization is more prone to applied functional forces. Repeated submaximal functional forces in an area of bony weakness, such as an endosseous implant site, may lead to a spontaneous fracture with no associated trauma. With these factors in mind, several extra precautions should be taken when implants are placed in thin or weak mandibles.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2406402     DOI: 10.1016/0278-2391(90)90401-m

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  5 in total

1.  Local complications in dental implant surgery: prevention and treatment.

Authors:  S Annibali; M Ripari; G LA Monaca; F Tonoli; M P Cristalli
Journal:  Oral Implantol (Rome)       Date:  2008-06-16

2.  No apparent association between dental implants and mandibular fractures resulting from external forces.

Authors:  Shunsuke Hino; Tateyuki Iizuka; Nikola Saulacic; Niklaus P Lang; John-Patrik M Burkhard
Journal:  Clin Oral Investig       Date:  2021-09-24       Impact factor: 3.573

3.  Mandibular fractures associated with endosteal implants.

Authors:  Bruno Ramos Chrcanovic; Antônio Luís Neto Custódio
Journal:  Oral Maxillofac Surg       Date:  2009-12

4.  Osteoradionecrosis of the jaws triggered by dental implants placement: A case report.

Authors:  Jorge Toledano-Serrabona; Gabriela Párraga-Manzol; Mª Ángeles Sánchez-Garcés; Cosme Gay-Escoda
Journal:  J Clin Exp Dent       Date:  2019-01-01

5.  Mandibular Fracture in a Hemifacial Microsomia Patient following Implant Failure and Hardware Infection: A Case Report.

Authors:  Kausar Ali; Rami P Dibbs; Renata S Maricevich
Journal:  Arch Plast Surg       Date:  2022-09-23
  5 in total