Literature DB >> 24060694

Evaluation of monoclonal antibody based immunochromatographic strip test for direct detection of Vibrio cholerae O1 contamination in seafood samples.

Parin Chaivisuthangkura1, Chalinan Pengsuk, Siwaporn Longyant, Paisarn Sithigorngul.   

Abstract

A strip test for the detection of Vibrio cholerae O1 was developed using two monoclonal antibodies (MAbs), VC-223 and VC-1226, specific to the lipopolysaccharides of Vibrio cholerae O1 Inaba and Ogawa serovars. The sensitivity of the test was 5 × 10(5)cfu/mL which was similar to that of dot blot test. The detection limit could be improved to 1cfu/mL of the original bacterial content after pre-incubation of the bacterium in alkaline peptone water (APW) for 12h. Detection of V. cholerae O1 in various fresh seafood samples such as shrimp, blood clam, mussel and oyster could be performed directly with sensitivities ranged from 5 × 10(5) to 10(6)cfu/mL. After pre-enrichment of the shrimp sample in APW, the detection sensitivities increased to 10(2) to 10CFU/mL of the original bacterial content after incubation for 12 and 24h. However, the detection sensitivities were also depending on the content of the other bacteria that might inhibit the growth of V. cholerae during pre-enrichment step. The V. cholerae O1 strip test has advantages in speed, and simplicity in not requiring sophisticated equipment or specialized skills and the sample could be directly examined without requirement for sample processing.
© 2013.

Entities:  

Keywords:  Immunochromatography; Monoclonal antibody (MAb); Strip test; Vibrio cholerae

Mesh:

Substances:

Year:  2013        PMID: 24060694     DOI: 10.1016/j.mimet.2013.09.013

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  3 in total

1.  Ultrasensitive Biosensor for the Detection of Vibrio cholerae DNA with Polystyrene-co-acrylic Acid Composite Nanospheres.

Authors:  Mahbubur Rahman; Lee Yook Heng; Dedi Futra; Tan Ling Ling
Journal:  Nanoscale Res Lett       Date:  2017-08-01       Impact factor: 4.703

2.  Simultaneous Lateral Flow Immunoassay for Multi-Class Chemical Contaminants in Maize and Peanut with One-Stop Sample Preparation.

Authors:  Du Wang; Jianguo Zhu; Zhaowei Zhang; Qi Zhang; Wen Zhang; Li Yu; Jun Jiang; Xiaomei Chen; Xuefang Wang; Peiwu Li
Journal:  Toxins (Basel)       Date:  2019-01-20       Impact factor: 4.546

Review 3.  Electrochemical Immuno- and Aptamer-Based Assays for Bacteria: Pros and Cons over Traditional Detection Schemes.

Authors:  Rimsha Binte Jamal; Stepan Shipovskov; Elena E Ferapontova
Journal:  Sensors (Basel)       Date:  2020-09-28       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.