Literature DB >> 24060424

Modulation of the foreign body response to implanted sensor models through device-based delivery of the tyrosine kinase inhibitor, masitinib.

Mahender Nath Avula1, Archana Nagaraja Rao, Lawrence D McGill, David William Grainger, Florian Solzbacher.   

Abstract

The host foreign body response (FBR) adversely effects the performance of numerous implanted biomaterials especially biosensors, including clinically popular glucose-monitoring sensors. Reactive formation of a fibrous capsule around implanted sensors hinders the transport of essential analytes to the sensor from the surrounding tissue, resulting in loss of glucose response sensitivity and eventual sensor failure. Several strategies have sought to mitigate the foreign body response's effects on CGM sensors through the use of local delivery of pharmaceuticals and biomolecules with limited success. This study describes release of a tyrosine kinase inhibitor - masitinib - from the sensor implant to target tissue resident mast cells as key mediators of the FBR. Model implants are coated with a composite polymer hydrophilic matrix that rapidly dissolves upon tissue implantation to deposit slower-degrading polymer microparticles containing masitinib. Matrix dissolution limits coating interference with sensor function while establishing a local controlled-release delivery depot formulation to alter implant tissue pharmacology and addressing the FBR. Drug efficacy was evaluated in a murine subcutaneous pocket implant model. Drug release extends to more than 30 days in vitro. The resulting FBR in vivo, evaluated by implant capsule thickness and inflammatory cell densities at 14, 21, and 28 days, displays statistically significant reduction in capsule thickness around masitinib-releasing implant sites compared to control implant sites.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomedical implants; Continuous glucose monitoring sensors; Foreign body response; Local drug delivery; Mast cells; Tyrosine kinase inhibitor

Mesh:

Substances:

Year:  2013        PMID: 24060424     DOI: 10.1016/j.biomaterials.2013.08.090

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  9 in total

Review 1.  In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility.

Authors:  Robert J Soto; Jackson R Hall; Micah D Brown; James B Taylor; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2016-11-21       Impact factor: 6.986

2.  A High Strength Self-Healable Antibacterial and Anti-Inflammatory Supramolecular Polymer Hydrogel.

Authors:  Hongbo Wang; Hui Zhu; Weigui Fu; Yinyu Zhang; Bing Xu; Fei Gao; Zhiqiang Cao; Wenguang Liu
Journal:  Macromol Rapid Commun       Date:  2017-03-08       Impact factor: 5.734

3.  Chondroitin Sulfate Immobilized on a Biomimetic Scaffold Modulates Inflammation While Driving Chondrogenesis.

Authors:  Bruna Corradetti; Francesca Taraballi; Silvia Minardi; Jeffrey Van Eps; Fernando Cabrera; Lewis W Francis; Salvatore A Gazze; Mauro Ferrari; Bradley K Weiner; Ennio Tasciotti
Journal:  Stem Cells Transl Med       Date:  2016-03-24       Impact factor: 6.940

4.  Nanoparticle delivery of miR-223 to attenuate macrophage fusion.

Authors:  Laura Beth Moore; Andrew J Sawyer; Jennifer Saucier-Sawyer; W Mark Saltzman; Themis R Kyriakides
Journal:  Biomaterials       Date:  2016-02-26       Impact factor: 12.479

5.  Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size.

Authors:  Yan Wang; Santhisagar Vaddiraju; Bing Gu; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2015-08-25

Review 6.  Modulating the foreign body response of implants for diabetes treatment.

Authors:  Bhushan N Kharbikar; Gauree S Chendke; Tejal A Desai
Journal:  Adv Drug Deliv Rev       Date:  2021-01-21       Impact factor: 17.873

7.  Antifouling Super Water Absorbent Supramolecular Polymer Hydrogel as an Artificial Vitreous Body.

Authors:  Hongbo Wang; Yuanhao Wu; Chunyan Cui; Jianhai Yang; Wenguang Liu
Journal:  Adv Sci (Weinh)       Date:  2018-09-25       Impact factor: 16.806

Review 8.  Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review.

Authors:  Daniela Rodrigues; Ana I Barbosa; Rita Rebelo; Il Keun Kwon; Rui L Reis; Vitor M Correlo
Journal:  Biosensors (Basel)       Date:  2020-07-21

Review 9.  Biodiagnostics in an era of global pandemics-From biosensing materials to data management.

Authors:  Yoav Y Broza; Hossam Haick
Journal:  View (Beijing)       Date:  2021-06-18
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.