Literature DB >> 24059576

MR Imaging in Multiple Sclerosis: The Accuracy of 3D Double Inversion Recovery at 3 Tesla and the Potential for Single Sequence Imaging.

S R Khangure1, M S Khangure.   

Abstract

To compare the accuracy of a three dimensional, T2-weighted double inversion recovery (DIR) sequence with two dimensional fluid attenuated inversion recovery (FLAIR) and dual echo T2 (DE T2) sequences at 3 Tesla in the detection of intracranial demyelinating lesions in patients with known or suspected multiple sclerosis (MS), and to consider the appropriateness of a stand-alone DIR sequence in MS imaging. The studies of 98 patients who underwent imaging with DE T2, FLAIR and DIR sequences for known or suspected multiple sclerosis were retrospectively reviewed. In 42 cases, a diagnosis of MS had been clinically suspected. In the remaining 56 cases, a diagnosis of MS had been previously established. All patients were imaged on a 3T MRI unit. Coronal and sagittal FLAIR, axial DE T2, and three dimensional T2-weighted DIR sequences were utilised. Of the 42 patients with suspected multiple sclerosis, 11 demonstrated lesions characteristic of the disease. Demyelinating plaques were seen in all of the 56 patients with known MS. In all cases, all lesions seen on DE T2-or FLAIR sequences were visible and more conspicuous on the DIR sequence. In 22 of the 67 patients (33%) with demyelinating lesions, the DIR sequence showed additional lesions not visible on any of the other sequences. Additional detected lesions predominantly involved grey matter. At 3 Tesla, a T2 weighted, three dimensional DIR sequence is as accurate at detecting the presence of intracranial demyelinating lesions as two dimensional FLAIR and DE T2 sequences combined. A greater number of lesions were detected with the DIR sequence, and all lesions were more conspicuous. A single, stand alone DIR sequence may be considered appropriate for monitoring MS.

Entities:  

Year:  2011        PMID: 24059576     DOI: 10.1177/197140091102400114

Source DB:  PubMed          Journal:  Neuroradiol J        ISSN: 1971-4009


  3 in total

1.  Magnetization transfer ratio in lesions rather than normal-appearing brain relates to disability in patients with multiple sclerosis.

Authors:  Michael Amann; Athina Papadopoulou; Michaela Andelova; Stefano Magon; Nicole Mueller-Lenke; Yvonne Naegelin; Christoph Stippich; Ernst Wilhelm Radue; Oliver Bieri; Ludwig Kappos; Till Sprenger
Journal:  J Neurol       Date:  2015-06-05       Impact factor: 4.849

2.  A novel imaging technique for better detecting new lesions in multiple sclerosis.

Authors:  Paul Eichinger; Hanni Wiestler; Haike Zhang; Viola Biberacher; Jan S Kirschke; Claus Zimmer; Mark Mühlau; Benedikt Wiestler
Journal:  J Neurol       Date:  2017-07-29       Impact factor: 4.849

3.  Double inversion recovery imaging of the brain: deriving the most relevant sequence through real images.

Authors:  Shunichi Motegi; Takehiro Shimada; Norio Hayashi; Hiroyuki Nagase; Ayako Taketomi-Takahashi; Yoshito Tsushima
Journal:  Radiol Phys Technol       Date:  2017-04-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.