Literature DB >> 24059379

Utility of dual-energy CT virtual keV monochromatic series for the assessment of spinal transpedicular hardware-bone interface.

Ashok Srinivasan1, Ellen Hoeffner, Mohannad Ibrahim, Gaurang V Shah, Frank LaMarca, Suresh K Mukherji.   

Abstract

OBJECTIVE: Our aim was to evaluate the utility of dual-energy CT (DECT) virtual kilo-electron volt (keV) monochromatic images for the visualization of the transpedicular screw-bone interface after spinal fusion.
MATERIALS AND METHODS: This retrospective study included postfusion spine CT studies performed from October 2011 through April 2012 on a dual-energy 64-MDCT unit (Discovery CT750 HD). Studies were postprocessed on an Advantage Windows workstation (version 4.4) by two neuroradiologists with creation of monochromatic images from 40 to 140 keV. Each reader graded the screw-bone interfaces on the 70-keV images (used for clinical interpretation) and on the monochromatic series using a 5-point scale (1 [uninterpretable] to 5 [excellent]). The grades of the interfaces were compared using the Wilcoxon signed rank test to detect differences between the 70-keV image and the monochromatic series.
RESULTS: Ninety-two transpedicular screws in 10 patients were studied. Significant improvement in the visibility of the hardware-bone interface was seen on the monochromatic series compared with the 70-keV images: The median grade for the monochromatic series was 4 (range, 2-5) for both readers, whereas the median grade for the 70-keV images was 3 (range, 2-4) for reader 1 and 2 (range, 2-3) for reader 2 (both, p < 0.001). The interobserver agreement using weighted kappa was 0.51 for grading screw-bone interface visualization. The volume CT dose index was 29.5 mGy in all patients and the mean dose-length product was 805.2 mGy × cm.
CONCLUSION: Monochromatic images generated on gemstone spectral DECT are beneficial in the reduction of metallic streak artifact and enable better visualization of the hardware-bone interface than the 70-keV series in patients treated with spinal transpedicular screw fixation.

Entities:  

Mesh:

Year:  2013        PMID: 24059379     DOI: 10.2214/AJR.12.9736

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  14 in total

1.  Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT.

Authors:  Yue Dong; Ai Jun Shi; Jian Lin Wu; Ru Xin Wang; Li Fei Sun; Ai Lian Liu; Yi Jun Liu
Journal:  Eur Spine J       Date:  2015-06-13       Impact factor: 3.134

2.  Different spectral hounsfield unit curve and high-energy virtual monochromatic image characteristics of squamous cell carcinoma compared with nonossified thyroid cartilage.

Authors:  R Forghani; M Levental; R Gupta; S Lam; N Dadfar; H D Curtin
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-05       Impact factor: 3.825

3.  Spectral CT imaging as a new quantitative tool? Assessment of perfusion defects of pulmonary parenchyma in patients with lung cancer.

Authors:  Ying-Shi Sun; Xiao-Yan Zhang; Yong Cui; Lei Tang; Xiao-Ting Li; Ying Chen; Xiao-Peng Zhang
Journal:  Chin J Cancer Res       Date:  2013-12       Impact factor: 5.087

Review 4.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Joel G Fletcher
Journal:  Radiology       Date:  2015-09       Impact factor: 11.105

5.  Deep-learning-based direct synthesis of low-energy virtual monoenergetic images with multi-energy CT.

Authors:  Hao Gong; Jeffrey F Marsh; Karen N D'Souza; Nathan R Huber; Kishore Rajendran; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  J Med Imaging (Bellingham)       Date:  2021-04-19

6.  Quantitative spectral CT evaluation of kidney tumors with the stretched-exponential nonlinear regression analysis model.

Authors:  Xiaotong Yang; Wenge Sun; Desheng Huang; Hui Li; Yu Zhao; Peiling Li; Yi Liu
Journal:  Quant Imaging Med Surg       Date:  2021-02

Review 7.  Dual-Energy CT: What the Neuroradiologist Should Know.

Authors:  Alida A Postma; Marco Das; Annika A R Stadler; Joachim E Wildberger
Journal:  Curr Radiol Rep       Date:  2015

8.  The Usefulness of Dual-Layer Spectral Computed Tomography for Myelography: A Case Report and Review of the Literature.

Authors:  Yuji Iyama; Takeshi Nakaura; Ayumi Iyama; Kazuhiro Katahira; Yasuyuki Yamashita
Journal:  Case Rep Orthop       Date:  2018-03-04

Review 9.  Multiparametric Evaluation of Head and Neck Squamous Cell Carcinoma Using a Single-Source Dual-Energy CT with Fast kVp Switching: State of the Art.

Authors:  Stephanie Lam; Rajiv Gupta; Hillary Kelly; Hugh D Curtin; Reza Forghani
Journal:  Cancers (Basel)       Date:  2015-11-06       Impact factor: 6.639

Review 10.  Dual-Energy CT in Head and Neck Imaging.

Authors:  Elise D Roele; Veronique C M L Timmer; Lauretta A A Vaassen; Anna M J L van Kroonenburgh; A A Postma
Journal:  Curr Radiol Rep       Date:  2017-03-29
View more