Literature DB >> 24059122

[Measurement of peak velocity variation of common carotid artery with bedside ultrasound to estimate preload in surgery ICU].

Wan-Hong Yin1, Yao Chen, Xiao-Dong Jin, Yan-Yan Zuo, Yan Kang, Bo Wang, Xue-Ying Zeng.   

Abstract

OBJECTIVE: To investigate the feasibility and accuracy of bedside ultrasound measuring peak velocity variation of common carotid artery to estimate preload of the patients in surgery ICU.
METHODS: In this prospective cohort study, SICU patients with sinus rhythm and positive pressure ventilation were included. The peak velocity variation in common carotid artery (delta V peak) during each respiratory circle was measured by ICU resident with short-term training and experienced attending songrapher. Stroke volume before and after the fluid challenge was also measured by the experienced songrapher as the gold standard of fluid responsiveness. Then the ROC, feasibility and accuracy of the diagnosis trial were analyzed.
RESULTS: There were 46 patients included. The peak velocity variation of common carotid artery measured by the attending (delta V peak) is highly related with delta SV (r1 = 0.76, P < 0.05). Area under the receiver operating characteristic curve was 0.95 (P < 0.05). The peak velocity variation of common carotid artery (delta V peak) > 12.1% predicted fluid responsiveness with sensitivity of 90.9%, specificity of 83.3%, positive predictive value of 83.3% and negative predictive value of 90.9%. The peak velocity variation of common carotid artery measured by the resident (delta V peak2) were highly related with delta V peak1 (R2 = 0.68, P < 0.05), the AUC was 0.94.
CONCLUSION: Measurement of peak velocity variation of common carotid artery with bedside ultrasound can accurately estimate the volume status of the patients in surgery ICU, and it is easy to be performed by the residents of ICU.

Entities:  

Mesh:

Year:  2013        PMID: 24059122

Source DB:  PubMed          Journal:  Sichuan Da Xue Xue Bao Yi Xue Ban        ISSN: 1672-173X


  1 in total

1.  Respiratory variation in peripheral arterial blood flow peak velocity to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis.

Authors:  Bo Yao; Jian-Yu Liu; Yun-Bo Sun
Journal:  BMC Anesthesiol       Date:  2018-11-13       Impact factor: 2.217