Literature DB >> 24056976

Microstructural and electrochemical impedance characterization of bio-functionalized ultrafine ZnS nanocrystals-reduced graphene oxide hybrid for immunosensor applications.

Sujeet K Mishra1, Avanish K Srivastava, Devendra Kumar, Ashok M Biradar.   

Abstract

We report a mercaptopropionic acid capped ZnS nanocrystals decorated reduced graphene oxide (RGO) hybrid film on a silane modified indium-tin-oxide glass plate, as a bioelectrode for the quantitative detection of human cardiac myoglobin (Ag-cMb). The ZnS nanocrystals were anchored over electrochemically reduced GO sheets through a cross linker, 1-pyrenemethylamine hydrochloride, by carbodiimide reaction and have been characterized by scanning electron microscopy, transmission electron microscopy and energy dispersive X-ray spectroscopy. The transmission electron microscopic characterization of the ZnS-RGO hybrid shows the uniform distribution of ultra-fine nanoparticles of ZnS in nano-sheets of GO throughout the material. The protein antibody, Ab-cMb, was covalently linked to ZnS-RGO nanocomposite hybrid for the fabrication of the bioelectrode. A detailed electrochemical immunosensing study has been carried out on the bioelectrode towards the detection of target Ag-cMb. The optimal fitted equivalent circuit model that matches the impedance response has been studied to delineate the biocompatibility, sensitivity and selectivity of the bioelectrode. The bioelectrode exhibited a linear electrochemical impedance response to Ag-cMb in a range of 10 ng to 1 μg mL(-1) in PBS (pH 7.4) with a sensitivity of 177.56 Ω cm(2) per decade. The combined synergistic effects of the high surface-to-volume ratio of ZnS(MPA) nanocrystals and conducting RGO has provided a dominant charge transfer characteristic (R(et)) at the lower frequency region of <10 Hz showing a good biocompatibility and enhanced impedance sensitivity towards target Ag-cMb. The impedance response sensitivity of the ZnS-RGO hybrid bioelectrode towards Ag-cMb has been found to be about 2.5 fold higher than that of a bare RGO modified bioelectrode.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24056976     DOI: 10.1039/c3nr02575f

Source DB:  PubMed          Journal:  Nanoscale        ISSN: 2040-3364            Impact factor:   7.790


  3 in total

1.  A glassy carbon electrode modified with a composite consisting of gold nanoparticle, reduced graphene oxide and poly(L-arginine) for simultaneous voltammetric determination of dopamine, serotonin and L-tryptophan.

Authors:  Md Zaved H Khan; Xiaoqiang Liu; Yunfei Tang; Jinhua Zhu; Weiping Hu; Xiuhua Liu
Journal:  Mikrochim Acta       Date:  2018-08-30       Impact factor: 5.833

Review 2.  An Overview of Carbon Nanotubes and Graphene for Biosensing Applications.

Authors:  Zanzan Zhu
Journal:  Nanomicro Lett       Date:  2017-02-07

3.  Preparation of ZnS@N-doped-carbon composites via a ZnS-amine precursor vacuum pyrolysis route.

Authors:  Wen-Hua Liao; Qian-Qian Hu; Min Cheng; Xiao-Hui Wu; Guang-Hao Zhan; Rui-Bo Yan; Jian-Rong Li; Xiao-Ying Huang
Journal:  RSC Adv       Date:  2021-10-11       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.