Glucocorticoid stress hormones and their artificial derivatives are widely used drugs to treat inflammation, but long-term treatment with glucocorticoids can lead to severe side effects. Test systems are needed to search for novel compounds influencing glucocorticoid signaling in vivo or to determine unwanted effects of compounds on the glucocorticoid signaling pathway. We have established a transgenic zebrafish assay which allows the measurement of glucocorticoid signaling activity in vivo and in real-time, the GRIZLY assay (Glucocorticoid Responsive In vivo Zebrafish Luciferase activitY). The luciferase-based assay detects effects on glucocorticoid signaling with high sensitivity and specificity, including effects by compounds that require metabolization or affect endogenous glucocorticoid production. We present here a detailed protocol for conducting chemical screens with this assay. We describe data acquisition, normalization, and analysis, placing a focus on quality control and data visualization. The assay provides a simple, time-resolved, and quantitative readout. It can be operated as a stand-alone platform, but is also easily integrated into high-throughput screening workflows. It furthermore allows for many applications beyond chemical screening, such as environmental monitoring of endocrine disruptors or stress research.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24056611 PMCID: PMC3967631 DOI: 10.3791/50439
Source DB: PubMed Journal: J Vis Exp ISSN: 1940-087X Impact factor: 1.355
|
| |||
|
| |||
|
| type: | single liquid | |
| mode: | blow out | ||
| dispenses per aspirate: | 1 | ||
| optimize for speed: | Yes | ||
| air gaps system: | 10 μl | ||
| transport: | 0 | ||
|
|
| ||
|
|
|
|
|
| Position | B7, B10, B13, B16 | ||
| Aspirate Vol. | 10 μl | ||
| Speed | 200 μl/sec | ||
| Liquid tracking | 60% | ||
| Aspirate Height | Labware default | 22.28 | |
|
|
|
|
|
| Positions | D7, D10, D13, D16 | ||
| Dispense Vol. | 10 μl | ||
| Speed | 200 μl/sec | ||
| Liquid tracking | 100 μl | ||
| Dispense Height | Labware default | 17.01 | |
|
| |||
|
|
|
| |
| mode: | waste | ||
| dispenses per aspirate: | 3 | ||
| optimize for speed: | Yes | ||
| air gaps system: | 15 μl | ||
| transport: | 0 | ||
|
|
| ||
|
|
|
|
|
| Position | A4 | ||
| Aspirate Vol. | 3 x 490 μl | ||
| Air gaps | 15 and 0 | ||
| Speed | 200 μl/sec | ||
| Liquid tracking | 400% | ||
| Aspirate Height | Liquid surface | ||
|
|
|
|
|
| Position | D7, D10, D13, D16 | ||
| Dispense Vol. | 490 μl | ||
| Air gaps | 15 and 0 | ||
| Speed | 200 μl/sec | ||
| Liquid tracking | 100% | ||
| Dispense Height | Labware default | 17.01 |
|
| |||
|
|
| ||
| Number of plates | unlimited | ||
| Temperature control | 28 °C | ||
|
|
| ||
|
| |||
| Measurement time | 2.5 sec | Crosstalk correction | |
| Distance between plate and detector | 0 mm | ||
| Glow (CT2) correction factor | 0 % |