Literature DB >> 24055902

Persistent corneal opacity after descemet stripping automated endothelial keratoplasty suggesting inert material deposits into the interface.

Priyanka Chhadva1, Florence Cabot, Noel Ziebarth, George D Kymionis, Sonia H Yoo.   

Abstract

PURPOSE: To report a case of interface deposits after Descemet stripping automated endothelial keratoplasty (DSAEK) imaged by means of an electron microscope.
METHODS: An 88-year-old man was referred with a history of corneal edema resulting from pseudophakic bullous keratopathy. A DSAEK was performed on his left eye without complications; however, the follow-up examination revealed a well-attached graft with persistent interface opacities at the donor-recipient interface. The DSAEK was repeated in this eye 1 year after the first surgery because of these corneal opacities that interfered with his vision.
RESULTS: In the immediate postoperative period, the patient had adequate visual acuity with intact graft placement and a clear interface. Pathology and electron microscope analysis were performed on the removed endothelial graft, which revealed diffuse particles on the stromal surface of the endothelial graft.
CONCLUSIONS: A repeated DSAEK procedure sufficiently removed this patient's corneal opacities and improved the visual acuity. The opacity is believed to have occurred because of residual viscoelastic material, which was used to maintain anterior chamber volume during surgery. This solution must be thoroughly removed to avoid similar complications.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24055902     DOI: 10.1097/ICO.0b013e3182a1bc49

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  2 in total

1.  Comparison of Descemet stripping under continuous air flow, manual air injection and balanced salt solution for DMEK: a pilot study.

Authors:  I E Gabbay; I Bahar; Y Nahum; E Livny
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-04-29       Impact factor: 3.117

2.  Surgical management of post-Descemet stripping automated endothelial keratoplasty interface haze associated with interface deposits.

Authors:  George D Kymionis; Nafsika Voulgari; George A Kontadakis; Dimitrios Mikropoulos; Aleksandra Petrovic; Konstantinos Droutsas
Journal:  Indian J Ophthalmol       Date:  2020-01       Impact factor: 1.848

  2 in total