Literature DB >> 24054632

Ionic liquid-based totally organic solvent-free emulsification microextraction coupled with high performance liquid chromatography for the determination of three acaricides in fruit juice.

Jiaheng Zhang1, Zhe Liang, Hao Guo, Peng Gao, Runhua Lu, Wenfeng Zhou, Sanbing Zhang, Haixiang Gao.   

Abstract

A novel, totally organic solvent-free emulsification microextraction (TEME) technique using ionic liquids (ILs) is proposed in this study. Seven bis(trifluoromethylsulfonyl)imide ionic liquids were synthesized. After comparing the physicochemical properties of the ionic liquids and their application to microextraction experiments, 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C6MIM][NTf2]), which has moderate surface tension and viscosity, was selected as the extraction solvent. The dispersion of ILs and mass transfer were accelerated by ultrasound irradiation and temperature control processes. Therefore, no dispersive organic solvent was needed. Several variables, such as ionic liquid volume, duration of the ultrasound extraction, dispersion temperature, ionic strength and centrifugation time were investigated and optimized. Under the optimum conditions, the calibration curve was linear in the range of 0.1-600 μg L(-1) for chlorfenapyr and fenpyroximate and 0.5-600 μg L(-1) for spirodiclofen, with correlation coefficients of 0.9994-0.9999. The enrichment factors were between 261 and 285. The limits of detection (LODs) were 0.02-0.06 μg L(-1). Real fruit juice samples (at fortified levels of 10 μg L(-1) and 30 μg L(-1)) were successfully analyzed using the proposed method. The relative recoveries and enrichment factors were in the range of 92-104%.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Acaricides; Ionic liquid; Liquid–liquid microextraction; Surface tension; Ultrasound irradiation

Mesh:

Substances:

Year:  2013        PMID: 24054632     DOI: 10.1016/j.talanta.2013.06.010

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Precision environmental health monitoring by longitudinal exposome and multi-omics profiling.

Authors:  Peng Gao; Xiaotao Shen; Xinyue Zhang; Chao Jiang; Sai Zhang; Xin Zhou; Sophia Miryam Schüssler-Fiorenza Rose; Michael Snyder
Journal:  Genome Res       Date:  2022-06-06       Impact factor: 9.438

2.  Novel hydrophobic deep eutectic solvent for vortex-assisted liquid phase microextraction of common acaricides in fruit juice followed by HPLC-UV determination.

Authors:  Setareh Rostami-Javanroudi; Masoud Moradi; Kiomars Sharafi; Nazir Fattahi
Journal:  RSC Adv       Date:  2021-09-09       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.