| Literature DB >> 24054610 |
Maciel S Luz1, Angerson N Nascimento, Pedro V Oliveira.
Abstract
A method for the simultaneous determination of Co, Cu, Pb and Se in crude oil, gasoline and diesel samples using emulsion-based sampling and GF AAS is proposed. 400mg of sample was weighted in volumetric flask following the sequential addition of 125 µL of hexane and 7.5 mL of Triton X-100(®) (20% mv(-1)). Subsequently, the mixture was stirred in ultrasonic bath, during 30 min, before dilution to 25 mL with deionized water. Aliquots of 20 μL of reference solution or sample emulsion were co-injected into the graphite tube with 10 μL of 2 g L(-1) Pd(NO3)2. The pyrolysis and atomization temperatures were 1300°C and 2250°C, respectively. The limits of detection (n=10, 3σ) and characteristic masses were 0.02 μg g(-1) (0.32 μg L(-1)) and 18 pg for Co, 0.03 μg g(-1) (0.48 μg L(-1)) and 15 pg for Cu, 0.04 μg g(-1) (0.64 μg L(-1)) and 48 pg for Pb, and 0.11 μg g(-1) (1.76 μg L(-1)) and 47 pg for Se. The reliabilities of the proposed method for Co and Se were checked by SRM(®) 1634c Residual Oil analysis. The found values are in accordance to the SRM at 95% confidence level (Student's t-test). Each sample was spiked with 0.18 μg g(-1) of Co, Cu, Pb and Se and the recoveries varied from 92% to 116% for Co, 83% to 117% for Cu, 72% to 117% for Pb, and 82% to 122% for Se.Entities:
Keywords: Atomic absorption spectrometry; Cobalt; Copper; Emulsion; Lead; Selenium; Simultaneous determination
Year: 2013 PMID: 24054610 DOI: 10.1016/j.talanta.2013.05.034
Source DB: PubMed Journal: Talanta ISSN: 0039-9140 Impact factor: 6.057