Literature DB >> 24052456

Sensitivity of compressed spectral arrays for detecting seizures in acutely ill adults.

Craig A Williamson1, Sarah Wahlster, Mouhsin M Shafi, M Brandon Westover.   

Abstract

BACKGROUND: Continuous EEG recordings (cEEGs) are increasingly used in evaluation of acutely ill adults. Pre-screening using compressed data formats, such as compressed spectral array (CSA), may accelerate EEG review. We tested whether screening with CSA can enable detection of seizures and other relevant patterns.
METHODS: Two individuals reviewed the CSA displays of 113 cEEGs. While blinded to the raw EEG data, they marked each visually homogeneous CSA segment. An independent experienced electroencephalographer reviewed the raw EEG within 60 s on either side of each mark and recorded any seizures (and isolated epileptiform discharges, periodic epileptiform discharges (PEDs), rhythmic delta activity (RDA), and focal or generalized slowing). Seizures were considered to have been detected if the CSA mark was within 60 s of the seizure. The electroencephalographer then determined the total number of seizures (and other critical findings) for each record by exhaustive, page-by-page review of the entire raw EEG.
RESULTS: Within each of the 39 cEEG recordings containing seizures, one CSA reviewer identified at least one seizure, while the second CSA reviewer identified 38/39 patients with seizures. The overall detection rate was 89.0 % of 1,190 total seizures. When present, an average of 87.9 % of seizures were detected per individual patient. Detection rates for other critical findings were as follows: epileptiform discharges, 94.0 %; PEDs, 100 %; RDA, 97.9 %; focal slowing, 100 %; and generalized slowing, 100 %.
CONCLUSIONS: CSA-guided review can support sensitive screening of critical pathological information in cEEG recordings. However, some patients with seizures may not be identified.

Entities:  

Mesh:

Year:  2014        PMID: 24052456      PMCID: PMC6794096          DOI: 10.1007/s12028-013-9912-4

Source DB:  PubMed          Journal:  Neurocrit Care        ISSN: 1541-6933            Impact factor:   3.210


  28 in total

Review 1.  Assessment of digital EEG, quantitative EEG, and EEG brain mapping: report of the American Academy of Neurology and the American Clinical Neurophysiology Society.

Authors:  M Nuwer
Journal:  Neurology       Date:  1997-07       Impact factor: 9.910

Review 2.  Which EEG patterns warrant treatment in the critically ill? Reviewing the evidence for treatment of periodic epileptiform discharges and related patterns.

Authors:  Derek J Chong; Lawrence J Hirsch
Journal:  J Clin Neurophysiol       Date:  2005-04       Impact factor: 2.177

3.  Frequency and predictors of nonconvulsive seizures during continuous electroencephalographic monitoring in critically ill children.

Authors:  Nathalie Jette; Jan Claassen; Ronald G Emerson; Lawrence J Hirsch
Journal:  Arch Neurol       Date:  2006-12

Review 4.  Data analysis for continuous EEG monitoring in the ICU: seeing the forest and the trees.

Authors:  Mark L Scheuer; Scott B Wilson
Journal:  J Clin Neurophysiol       Date:  2004 Sep-Oct       Impact factor: 2.177

Review 5.  Status epilepticus and the use of continuous EEG monitoring in the intensive care unit.

Authors:  Thomas P Bleck
Journal:  Continuum (Minneap Minn)       Date:  2012-06

6.  Increased incidence and impact of nonconvulsive and convulsive seizures after traumatic brain injury as detected by continuous electroencephalographic monitoring.

Authors:  P M Vespa; M R Nuwer; V Nenov; E Ronne-Engstrom; D A Hovda; M Bergsneider; D F Kelly; N A Martin; D P Becker
Journal:  J Neurosurg       Date:  1999-11       Impact factor: 5.115

7.  Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates.

Authors:  Mona C Toet; Wil van der Meij; Linda S de Vries; Cuno S P M Uiterwaal; Kees C van Huffelen
Journal:  Pediatrics       Date:  2002-05       Impact factor: 7.124

Review 8.  Nonconvulsive status epilepticus in acute brain injury.

Authors:  K G Jordan
Journal:  J Clin Neurophysiol       Date:  1999-07       Impact factor: 2.177

9.  Continuous electroencephalography in the medical intensive care unit.

Authors:  Mauro Oddo; Emmanuel Carrera; Jan Claassen; Stephan A Mayer; Lawrence J Hirsch
Journal:  Crit Care Med       Date:  2009-06       Impact factor: 7.598

10.  Non-expert use of the cerebral function monitor for neonatal seizure detection.

Authors:  J M Rennie; G Chorley; G B Boylan; R Pressler; Y Nguyen; R Hooper
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2004-01       Impact factor: 5.747

View more
  16 in total

1.  Spectrogram screening of adult EEGs is sensitive and efficient.

Authors:  Lidia M V R Moura; Mouhsin M Shafi; Marcus Ng; Sandipan Pati; Sydney S Cash; Andrew J Cole; Daniel Brian Hoch; Eric S Rosenthal; M Brandon Westover
Journal:  Neurology       Date:  2014-05-23       Impact factor: 9.910

2.  Can We Screen EEGs More Efficiently? Spectrographic Review of EEG Data.

Authors:  Chad Carlson
Journal:  Epilepsy Curr       Date:  2015 Jan-Feb       Impact factor: 7.500

3.  A standardized nomenclature for spectrogram EEG patterns: Inter-rater agreement and correspondence with common intensive care unit EEG patterns.

Authors:  Sahar F Zafar; Edilberto Amorim; Craig A Williamsom; Jin Jing; Emily J Gilmore; Hiba A Haider; Christa Swisher; Aaron Struck; Eric S Rosenthal; Marcus Ng; Sarah Schmitt; Jong W Lee; M Brandon Westover
Journal:  Clin Neurophysiol       Date:  2020-06-24       Impact factor: 3.708

4.  Consensus statement on continuous EEG in critically ill adults and children, part II: personnel, technical specifications, and clinical practice.

Authors:  Susan T Herman; Nicholas S Abend; Thomas P Bleck; Kevin E Chapman; Frank W Drislane; Ronald G Emerson; Elizabeth E Gerard; Cecil D Hahn; Aatif M Husain; Peter W Kaplan; Suzette M LaRoche; Marc R Nuwer; Mark Quigg; James J Riviello; Sarah E Schmitt; Liberty A Simmons; Tammy N Tsuchida; Lawrence J Hirsch
Journal:  J Clin Neurophysiol       Date:  2015-04       Impact factor: 2.177

5.  Performance of Spectrogram-Based Seizure Identification of Adult EEGs by Critical Care Nurses and Neurophysiologists.

Authors:  Edilberto Amorim; Craig A Williamson; Lidia M V R Moura; Mouhsin M Shafi; Nicolas Gaspard; Eric S Rosenthal; Mary M Guanci; Venkatakrishna Rajajee; M Brandon Westover
Journal:  J Clin Neurophysiol       Date:  2017-07       Impact factor: 2.177

6.  Detection of electrographic seizures by critical care providers using color density spectral array after cardiac arrest is feasible.

Authors:  Alexis A Topjian; Michael Fry; Abbas F Jawad; Susan T Herman; Vinay M Nadkarni; Rebecca Ichord; Robert A Berg; Dennis J Dlugos; Nicholas S Abend
Journal:  Pediatr Crit Care Med       Date:  2015-06       Impact factor: 3.624

7.  Seizure Detection by Critical Care Providers Using Amplitude-Integrated Electroencephalography and Color Density Spectral Array in Pediatric Cardiac Arrest Patients.

Authors:  Geneviève Du Pont-Thibodeau; Sarah M Sanchez; Abbas F Jawad; Vinay M Nadkarni; Robert A Berg; Nicholas S Abend; Alexis A Topjian
Journal:  Pediatr Crit Care Med       Date:  2017-04       Impact factor: 3.624

8.  Inter-rater agreement on identification of electrographic seizures and periodic discharges in ICU EEG recordings.

Authors:  J J Halford; D Shiau; J A Desrochers; B J Kolls; B C Dean; C G Waters; N J Azar; K F Haas; E Kutluay; G U Martz; S R Sinha; R T Kern; K M Kelly; J C Sackellares; S M LaRoche
Journal:  Clin Neurophysiol       Date:  2014-11-20       Impact factor: 3.708

9.  Sensitivity of quantitative EEG for seizure identification in the intensive care unit.

Authors:  Hiba A Haider; Rosana Esteller; Cecil D Hahn; M Brandon Westover; Jonathan J Halford; Jong W Lee; Mouhsin M Shafi; Nicolas Gaspard; Susan T Herman; Elizabeth E Gerard; Lawrence J Hirsch; Joshua A Ehrenberg; Suzette M LaRoche
Journal:  Neurology       Date:  2016-07-27       Impact factor: 9.910

10.  Quantitative Continuous EEG: Bridging the Gap Between the ICU Bedside and the EEG Interpreter.

Authors:  Andreas H Kramer; Julie Kromm
Journal:  Neurocrit Care       Date:  2019-06       Impact factor: 3.210

View more