Literature DB >> 24048712

Impact of fluid-structure interaction on direct tumor-targeting in a representative hepatic artery system.

Emily M Childress1, Clement Kleinstreuer.   

Abstract

Direct targeting of solid tumors with chemotherapeutic drugs and/or radioactive microspheres can be a treatment option which minimizes side-effects and reduces cost. Briefly, computational analysis generates particle release maps (PRMs) which visually link upstream particle injection regions in the main artery with associated exit branches, some connected to tumors. The overall goal is to compute patient-specific PRMs realistically, accurately, and cost-effectively, which determines the suitable radial placement of a micro-catheter for optimal particle injection. Focusing in this paper on new steps towards realism and accuracy, the impact of fluid-structure interaction on direct drug-targeting is evaluated, using a representative hepatic artery system with liver tumor as a test bed. Specifically, the effect of arterial wall motion was demonstrated by modeling a two-way fluid-structure interaction analysis with Lagrangian particle tracking in the bifurcating arterial system. Clearly, rapid computational evaluation of optimal catheter location for tumor-targeting in a clinical application is very important. Hence, rigid-wall cases were also compared to the flexible scenario to establish whether PRMs generated when based on simplifying assumptions could provide adequate guidance towards ideal catheter placement. It was found that the best rigid (i.e., time-averaged) geometry is the physiological one that occurs during the diastolic targeting interval.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24048712     DOI: 10.1007/s10439-013-0910-7

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  5 in total

Review 1.  Drug-targeting methodologies with applications: A review.

Authors:  Clement Kleinstreuer; Yu Feng; Emily Childress
Journal:  World J Clin Cases       Date:  2014-12-16       Impact factor: 1.337

Review 2.  Particle Distribution in Embolotherapy, How Do They Get There? A Critical Review of the Factors Affecting Arterial Distribution of Embolic Particles.

Authors:  Reza Talaie; Pooya Torkian; Omid Amili; Yasmina Aboufirass; Nassir Rostambeigi; Hamed Jalaeian; Jafar Golzarian
Journal:  Ann Biomed Eng       Date:  2022-05-06       Impact factor: 3.934

3.  A Hybrid Particle-Flow CFD Modeling Approach in Truncated Hepatic Arterial Trees for Liver Radioembolization: A Patient-specific Case Study.

Authors:  Tim Bomberna; Saar Vermijs; Maryse Lejoly; Chris Verslype; Lawrence Bonne; Geert Maleux; Charlotte Debbaut
Journal:  Front Bioeng Biotechnol       Date:  2022-05-30

4.  Direct nanodrug delivery for tumor targeting subject to shear-augmented diffusion in blood flow.

Authors:  Zelin Xu; Clement Kleinstreuer
Journal:  Med Biol Eng Comput       Date:  2018-04-26       Impact factor: 2.602

Review 5.  Computational Fluid Dynamics Modeling of Liver Radioembolization: A Review.

Authors:  Jorge Aramburu; Raúl Antón; Macarena Rodríguez-Fraile; Bruno Sangro; José Ignacio Bilbao
Journal:  Cardiovasc Intervent Radiol       Date:  2021-09-13       Impact factor: 2.740

  5 in total