Literature DB >> 24048633

Validation of a new radiographic protocol for Asian elephant feet and description of their radiographic anatomy.

C Mumby1, T Bouts, L Sambrook, S Danika, E Rees, A Parry, M Rendle, N Masters, R Weller.   

Abstract

Foot problems are extremely common in elephants and radiography is the only imaging method available but the radiographic anatomy has not been described in detail. The aims of this study were to develop a radiographic protocol for elephant feet using digital radiography, and to describe the normal radiographic anatomy of the Asian elephant front and hind foot. A total of fifteen cadaver foot specimens from captive Asian elephants were radiographed using a range of projections and exposures to determine the best radiographic technique. This was subsequently tested in live elephants in a free-contact setting. The normal radiographic anatomy of the Asian elephant front and hind foot was described with the use of three-dimensional models based on CT reconstructions. The projection angles that were found to be most useful were 65-70° for the front limb and 55-60° in the hind limb. The beam was centred 10-15 cm proximal to the cuticle in the front and 10-15 cm dorsal to the plantar edge of the sole in the hind foot depending on the size of the foot. The protocol developed can be used for larger-scale diagnostic investigations of captive elephant foot disorders, while the normal radiographic anatomy described can improve the diagnostic reliability of elephant feet radiography.

Entities:  

Keywords:  Anatomy; Elephants; Foot conditions; Imaging; Radiography; Radiology

Mesh:

Year:  2013        PMID: 24048633     DOI: 10.1136/vr.101696

Source DB:  PubMed          Journal:  Vet Rec        ISSN: 0042-4900            Impact factor:   2.695


  2 in total

1.  Skeletal pathology and variable anatomy in elephant feet assessed using computed tomography.

Authors:  Sophie Regnault; Jonathon J I Dixon; Chris Warren-Smith; John R Hutchinson; Renate Weller
Journal:  PeerJ       Date:  2017-01-18       Impact factor: 2.984

2.  Rhinoceros feet step out of a rule-of-thumb: a wildlife imaging pioneering approach of synchronized computed tomography-digital radiography.

Authors:  Gabriela Galateanu; Robert Hermes; Joseph Saragusty; Frank Göritz; Romain Potier; Baptiste Mulot; Alexis Maillot; Pascal Etienne; Rui Bernardino; Teresa Fernandes; Jurgen Mews; Thomas Bernd Hildebrandt
Journal:  PLoS One       Date:  2014-06-25       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.