Literature DB >> 24047289

The ability of bispectral index to detect intra-operative wakefulness during isoflurane/air anaesthesia, compared with the isolated forearm technique.

I F Russell1.   

Abstract

Clinical signs are unreliable for guiding anaesthetic administration and it is suggested that using the bispectral index can improve anaesthetic delivery. In the current study, isoflurane administration was guided to a bispectral index range of 55-60. Intra-operative responsiveness, as assessed by the isolated forearm technique, was compared with whether the bispectral index predicted/identified a patient's appropriate hand movements in response to commands. Thirty-four women underwent major gynaecological surgery with isoflurane/air and atracurium. Eleven women responded on 32 occasions with appropriate hand movements to commands given during surgery, of which the bispectral index detected 17 (sensitivity 53%). The bispectral index suggested consciousness 660 times in the absence of any movement responses (specificity 69%). The positive predictive value of the bispectral index was 3%. The median (IQR [range]) bispectral index value associated with an intra-operative response was significantly lower than that associated with eye opening after surgery: 60 (50-68 [36-83]) vs 77 (75-84 [59-90]), respectively (p = 2.25 × 10(-8)). Conversely, end-tidal isoflurane concentration was significantly higher at intra-operative response than at eye opening: 0.3 (0.3-0.4 [0.2-0.9]) vs 0.2 (0.1-0.2 [0.1-0.3]), respectively (p = 7.36 × 10(-8)). For patients who responded more than once during surgery, the bispectral index value associated with a response was not constant. No patient had recall for surgery or the taped commands, and only one could remember dreaming (a good dream). Titrating isoflurane to target a bispectral index range of 55-60 may result in an unacceptable number of patients who are conscious during surgery (albeit without recall).
© 2013 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24047289     DOI: 10.1111/anae.12357

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  3 in total

Review 1.  Use of Processed Electroencephalography in the Clinical Setting.

Authors:  David A Mulvey; Peter Klepsch
Journal:  Curr Anesthesiol Rep       Date:  2020-10-23

2.  Optimal level of bispectral index for conscious sedation in awake fiberoptic nasotracheal intubation.

Authors:  Hari Haran Gnaneswaran; Gaurav Jain; Ankit Agarwal; Ashi Chug; Deepak Singla
Journal:  J Oral Biol Craniofac Res       Date:  2020-06-22

3.  The Study of Intraoperative Consciousness after Tracheal Intubation.

Authors:  Leena Harshad Parate; Sandyarani D Channaiah; Geetha C Rajappa; Rahul Singh; Akshara Madhav; Mariam Mahdiyyah
Journal:  Anesth Essays Res       Date:  2018 Oct-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.