Literature DB >> 24045999

Outcome study of real-time MR-guided cervical periradicular injection therapy in an open 1.0 Tesla MRI system.

Martin H Maurer1, Alexander C Disch, Tony Hartwig, Diane M Renz, Nils Schreiter, B Hamm, Florian Streitparth.   

Abstract

PURPOSE: To evaluate the accuracy, safety, and efficacy of cervical nerve root injection therapy using magnetic resonance guidance in an open 1.0 T MRI system.
METHODS: Between September 2009 and April 2012, a total of 21 patients (9 men, 12 women; mean age 47.1 ± 11.1 years) underwent MR-guided cervical periradicular injection for cervical radicular pain in an open 1.0 T system. An interactive proton density-weighted turbo spin echo (PDw TSE) sequence was used for real-time guidance of the MR-compatible 20-gauge injection needle. Clinical outcome was evaluated on a verbal numeric rating scale (VNRS) before injection therapy (baseline) and at 1 week and 1, 3, and 6 months during follow-up.
RESULTS: All procedures were technically successful and there were no major complications. The mean preinterventional VNRS score was 7.42 and exhibited a statistically significant decrease (P < 0.001) at all follow-up time points: 3.86 ± 1.53 at 1 week, 3.21 ± 2.19 at 1 month, 2.58 ± 2.54 at 3 months, and 2.76 ± 2.63 at 6 months. At 6 months, 14.3 % of the patients reported complete resolution of radicular pain and 38.1 % each had either significant (4-8 VNRS score points) or mild (1-3 VNRS score points) relief of pain; 9.5 % experienced no pain relief.
CONCLUSION: Magnetic resonance fluoroscopy-guided periradicular cervical spine injection is an accurate, safe, and efficacious treatment option for patients with cervical radicular pain. The technique may be a promising alternative to fluoroscopy- or CT-guided injections of the cervical spine, especially in young patients and in patients requiring repeat injections.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24045999     DOI: 10.1007/s00270-013-0738-4

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  2 in total

1.  MRI guidance technology development in a large animal model for hyperlocal analgesics delivery to the epidural space and dorsal root ganglion.

Authors:  Timothy P Maus; Joel P Felmlee; Mark D Unger; Andreas S Beutler
Journal:  J Neurosci Methods       Date:  2018-12-01       Impact factor: 2.390

2.  Real-time MR-guided brain biopsy using 1.0-T open MRI scanner.

Authors:  Xiangmeng He; Ming Liu; Chao Liu; Jing Fang; Yujun Xu; Ligang Wang; Jianfeng Xiang; Roberto Blanco Sequeiros; Chengli Li
Journal:  Eur Radiol       Date:  2018-06-12       Impact factor: 5.315

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.