Literature DB >> 24045248

Caudocranial scan direction and patient-specific injection protocols optimize ECG-gated and non-gated thoracic CTA.

Charbel Saade1, Roger Bourne, Mark Wilkinson, Michael Evanoff, Patrick C Brennan.   

Abstract

OBJECTIVES: Caudocranial scan direction and contrast injection timing based on measured patient vessel dynamics can significantly improve artery opacification and reduce contrast dose in the assessment of acute aortic syndrome using gated and non-gated thoracic CTA. This study aimed to investigate enhancement of the thoracic aorta using caudocranial scan direction and a patient-specific contrast regimen.
METHODS: Electrocardiogram-gated (n = 120) and non-gated (n = 200) thoracic computed tomography angiography was performed on patients with nontraumatic acute aortic syndrome. Patients were assigned to one of 2 acquisition/contrast regimens, namely, regimen A, craniocaudal scan direction with 120 mL contrast, and regimen B, caudocranial scan direction using a patient-specific contrast formula. Opacity of 9 arterial and venous segments was measured, arteriovenous contrast ratio calculated, and values compared using Mann-Whitney U statistics. Receiver operating characteristic analyses and visual grading characteristic assessed diagnostic efficacy and clinical image quality. Interobserver variations were investigated using κ methods.
RESULTS: Regimen B when compared to A, for both scanning/contrast techniques, demonstrated higher opacification in the aorta (P < 0.01) and lower opacification in the venous system (P < 0.0001). For protocol B, arteriovenous contrast ratio was significantly increased (P < 0.0001) and mean contrast volume reduced (P < 0.05) during gated [94 (10 mL)] and non-gated [78 (5 mL)] thoracic computed tomography angiography compared to A. Receiver operating characteristic analysis Az scores and interobserver agreement were significantly higher with regimen B than A (P < 0.05).
CONCLUSIONS: Caudocranial scan direction and injection timing based on patient-specific vessel dynamics can optimize artery opacification and diagnostic efficacy while reducing contrast volumes.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24045248     DOI: 10.1097/RCT.0b013e31829e02b9

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  6 in total

Review 1.  Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.

Authors:  Charbel Saade; Ibrahim Alsheikh Deeb; Maha Mohamad; Hussain Al-Mohiy; Fadi El-Merhi
Journal:  Diagn Interv Radiol       Date:  2016 Mar-Apr       Impact factor: 2.630

2.  Head and neck angiography at 70 kVp with a third-generation dual-source CT system in patients: comparison with 100 kVp.

Authors:  Yu Chen; Xiaobo Zhang; Huadan Xue; Yuanli Zhu; Yun Wang; Yumei Li; Zhuhua Zhang; Zhengyu Jin
Journal:  Neuroradiology       Date:  2017-08-24       Impact factor: 2.804

3.  Impact of various iodine concentrations of iohexol and iodixanol contrast media on image reconstruction techniques in a vascular-specific contrast media phantom: quantitative and qualitative image quality assessment.

Authors:  Charbel Saade; Lina Karout; Khalil El Asmar; Lena Naffaa; Fadi El Merhi; Rida Salman; Alain S Abi-Ghanem
Journal:  Radiol Med       Date:  2020-07-15       Impact factor: 3.469

4.  MDCT Venography Evaluation of a Rare Collateral Vein Draining from the Left Subclavian Vein to the Great Cardiac Vein.

Authors:  Antoine Abchee; Charbel Saade; Hussain Al-Mohiy; Fadi El-Merhi
Journal:  J Clin Imaging Sci       Date:  2014-10-27

5.  An augmented patient-specific approach to administration of contrast agent for CT renal angiography.

Authors:  Charbel Saade; Nadine Hamieh; Ibrahim Al-Sheikh Deeb; Maurice Haddad; Alain S Abi-Ghanem; Diamond Ghieh; Fadi El-Merhi
Journal:  Int Braz J Urol       Date:  2019 Sep-Oct       Impact factor: 1.541

6.  Split-bolus contrast injection protocol enhances the visualization of the thoracic vasculature and reduced radiation dose during chest CT.

Authors:  Salah Zein-El-Dine; Imad Bou Akl; Maha Mohamad; Ahmad Chmaisse; Stephanie Chahwan; Karl Asmar; Fadi El-Merhi; Charbel Saade
Journal:  Br J Radiol       Date:  2018-10-01       Impact factor: 3.039

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.