Cornelia Ottiger1, Nicole Gygli, Andreas R Huber. 1. Cantonal Hospital of Aarau, Department of Laboratory Medicine, CH-5001 Aarau, Switzerland. Electronic address: cornelia.ottiger@ksa.ch.
Abstract
BACKGROUND: hepatitis C infections are detected by anti-HCV screening tests. Reactive anti-HCV results give no information about the presence or absence of hepatitis C viruses, or of unspecific reactivity. To obtain information about the viral load, HCV RNA measurements, following a reactive anti-HCV result, are performed in well equipped and specialised laboratories. Anti-HCV immunoblots are the only means to exclude non specific reactivity. The measurement of HCV core antigen (HCV-Ag), as an alternative to HCV RNA, is discussed, as it can be analysed on the same instrument as anti-HCV. OBJECTIVES: The detection limit of HCV-Ag is crucial to use it in lieu of HCV RNA, in regard of the different genotypes. A renewed algorithm is proposed to exclude unspecific reactivity of anti-HCV. STUDY DESIGNS: Samples were tested on Architect i2000SR (Abbott) for anti-HCV and HCV-Ag. HCV RNA measurements were obtained by Cobas Ampliprep/Taqman (Roche) or m2000rt(®) (Abbott). RESULTS AND CONCLUSIONS: Comparison between HCV-Ag and HCV RNA from 126 samples of 101 patients with chronic hepatitis C gave linear regression R(2) 0.89, slope 0.885 and intercept -2.258, which were independent of the genotypes. The detection limit of HCV-Ag was between 2.4 and 4.5 Log(10)IU/mL. A renewed algorithm for confirmation of reactive anti-HCV results is proposed: active or resolved hepatitis C infections or false reactivity can be differentiated by sequenced reflex testing due to HCV-Ag, anti-HCV immunoblot and HCV RNA.
BACKGROUND:hepatitis C infections are detected by anti-HCV screening tests. Reactive anti-HCV results give no information about the presence or absence of hepatitis C viruses, or of unspecific reactivity. To obtain information about the viral load, HCV RNA measurements, following a reactive anti-HCV result, are performed in well equipped and specialised laboratories. Anti-HCV immunoblots are the only means to exclude non specific reactivity. The measurement of HCV core antigen (HCV-Ag), as an alternative to HCV RNA, is discussed, as it can be analysed on the same instrument as anti-HCV. OBJECTIVES: The detection limit of HCV-Ag is crucial to use it in lieu of HCV RNA, in regard of the different genotypes. A renewed algorithm is proposed to exclude unspecific reactivity of anti-HCV. STUDY DESIGNS: Samples were tested on Architect i2000SR (Abbott) for anti-HCV and HCV-Ag. HCV RNA measurements were obtained by Cobas Ampliprep/Taqman (Roche) or m2000rt(®) (Abbott). RESULTS AND CONCLUSIONS: Comparison between HCV-Ag and HCV RNA from 126 samples of 101 patients with chronic hepatitis C gave linear regression R(2) 0.89, slope 0.885 and intercept -2.258, which were independent of the genotypes. The detection limit of HCV-Ag was between 2.4 and 4.5 Log(10)IU/mL. A renewed algorithm for confirmation of reactive anti-HCV results is proposed: active or resolved hepatitis C infections or false reactivity can be differentiated by sequenced reflex testing due to HCV-Ag, anti-HCV immunoblot and HCV RNA.
Authors: Syria Laperche; C Micha Nübling; Susan L Stramer; Ewa Brojer; Piotr Grabarczyk; Hiroshi Yoshizawa; Vytenis Kalibatas; Magdy El Elkyabi; Faten Moftah; Annie Girault; Harry van Drimmelen; Michael P Busch; Nico Lelie Journal: Transfusion Date: 2015-05-27 Impact factor: 3.157
Authors: J Morgan Freiman; Trang M Tran; Samuel G Schumacher; Laura F White; Stefano Ongarello; Jennifer Cohn; Philippa J Easterbrook; Benjamin P Linas; Claudia M Denkinger Journal: Ann Intern Med Date: 2016-06-21 Impact factor: 25.391
Authors: Linh Thuy Nguyen; Linda Dunford; Ines Freitas; Paul Holder; Lan Anh Nguyen; Joanne O'Gorman; Jeff Connell; Michael Carr; William Hall; Cillian De Gascun Journal: J Clin Microbiol Date: 2015-05-20 Impact factor: 5.948