SPECT dual-energy-window Compton correction: scatter multiplier required for quantification.

K F Koral1, F M Swailem, S Buchbinder, N H Clinthorne, W L Rogers, B M Tsui.   

Abstract

The dual-energy window Compton-scattering correction technique is defined here especially for accurate quantification of focal regions having higher than average uptake. The quantification is relative to a known-activity reference source. The scatter multiplier ("k" value) is determined for a radioactive 99mTc sphere on or off the axis of a cylinder containing water with or without background. Both maximum likelihood and filtered-backprojection reconstruction are employed. Either projections or tomograms are corrected. With tight regions of interest, there is a tendency for the requisite "k" value to be slightly lower as the diameter of the cylinder is increased. Neither sphere location nor background perturbs "k", however, so a constant value is a good, first approximation. Then a two-sphere validation test yields an accuracy of 8% with subtracted-tomograms ("k" = 1.30) and 2% with subtracted-projections ("k" = 1.20). With a reference-source region of interest which is four times larger, "k" is reduced and also now depends on background. Although equivalent quantitatively, maximum likelihood is preferable to filtered backprojection with Chang attenuation correction since it produces a less-noisy image.

Entities:  

Mesh:

Year:  1990        PMID: 2404095

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  20 in total

1.  Correction of scattered photons in Tc-99m imaging by means of a photopeak dual-energy window acquisition.

Authors:  A Kojima; A Tsuji; Y Takaki; S Tomiguchi; M Hara; M Matsumoto; M Takahashi
Journal:  Ann Nucl Med       Date:  1992-08       Impact factor: 2.668

2.  Optimized acquisition and processing protocols for I-123 cardiac SPECT imaging.

Authors:  Ji Chen; Ernest V Garcia; James R Galt; Russell D Folks; Ignasi Carrio
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

Review 3.  What is the current status of quantification and nuclear medicine in cardiology?

Authors:  G Hör
Journal:  Eur J Nucl Med       Date:  1996-07

4.  Transmission-based scatter correction of 180 degrees myocardial single-photon emission tomographic studies.

Authors:  B F Hutton; A Osiecki; S R Meikle
Journal:  Eur J Nucl Med       Date:  1996-10

5.  Validation of a calibration method using the cross-calibration factor and system planar sensitivity in quantitative single-photon emission computed tomography imaging.

Authors:  Norikazu Matsutomo; Saki Matsumoto; Tomoaki Yamamoto; Eisuke Sato
Journal:  Radiol Phys Technol       Date:  2017-08-18

6.  Simulation study of triple-energy-window scatter correction in combined Tl-201, Tc-99m SPECT.

Authors:  K Ogawa
Journal:  Ann Nucl Med       Date:  1994-11       Impact factor: 2.668

7.  A comparative study of scatter correction methods for scintigraphic images.

Authors:  F Bonnin; I Buvat; H Benali; R Di Paola
Journal:  Eur J Nucl Med       Date:  1994-05

Review 8.  Scatter correction in scintigraphy: the state of the art.

Authors:  I Buvat; H Benali; A Todd-Pokropek; R Di Paola
Journal:  Eur J Nucl Med       Date:  1994-07

9.  Optimal collimator choice for sequential iodine-123 and technetium-99m imaging.

Authors:  F D Geeter; P R Franken; M Defrise; H Andries; E Saelens; A Bossuyt
Journal:  Eur J Nucl Med       Date:  1996-07

10.  Importance of intra-therapy single-photon emission tomographic imaging in calculating tumour dosimetry for a lymphoma patient.

Authors:  K F Koral; K R Zasadny; F M Swailem; S F Buchbinder; I R Francis; M S Kaminski; R L Wahl
Journal:  Eur J Nucl Med       Date:  1991
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.