Literature DB >> 24037179

Determining the ventilation and aerosol deposition rates from routine indoor-air measurements.

Christos H Halios1, Costas G Helmis, Katerina Deligianni, Sterios Vratolis, Konstantinos Eleftheriadis.   

Abstract

Measurement of air exchange rate provides critical information in energy and indoor-air quality studies. Continuous measurement of ventilation rates is a rather costly exercise and requires specific instrumentation. In this work, an alternative methodology is proposed and tested, where the air exchange rate is calculated by utilizing indoor and outdoor routine measurements of a common pollutant such as SO2, whereas the uncertainties induced in the calculations are analytically determined. The application of this methodology is demonstrated, for three residential microenvironments in Athens, Greece, and the results are also compared against ventilation rates calculated from differential pressure measurements. The calculated time resolved ventilation rates were applied to the mass balance equation to estimate the particle loss rate which was found to agree with literature values at an average of 0.50 h(-1). The proposed method was further evaluated by applying a mass balance numerical model for the calculation of the indoor aerosol number concentrations, using the previously calculated ventilation rate, the outdoor measured number concentrations and the particle loss rates as input values. The model results for the indoors' concentrations were found to be compared well with the experimentally measured values.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24037179     DOI: 10.1007/s10661-013-3362-5

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  6 in total

1.  Air quality guidelines for Europe.

Authors: 
Journal:  WHO Reg Publ Eur Ser       Date:  2000

2.  Mathematical modeling of chemically reactive pollutants in indoor air.

Authors:  W W Nazaroff; G R Cass
Journal:  Environ Sci Technol       Date:  1986-09-01       Impact factor: 9.028

3.  Infiltration of outdoor ultrafine particles into a test house.

Authors:  Donghyun Rim; Lance Wallace; Andrew Persily
Journal:  Environ Sci Technol       Date:  2010-08-01       Impact factor: 9.028

4.  Particle deposition in indoor environments: analysis of influencing factors.

Authors:  Bin Zhao; Jun Wu
Journal:  J Hazard Mater       Date:  2007-01-13       Impact factor: 10.588

Review 5.  Ventilation rates and health: multidisciplinary review of the scientific literature.

Authors:  J Sundell; H Levin; W W Nazaroff; W S Cain; W J Fisk; D T Grimsrud; F Gyntelberg; Y Li; A K Persily; A C Pickering; J M Samet; J D Spengler; S T Taylor; C J Weschler
Journal:  Indoor Air       Date:  2011-02-01       Impact factor: 5.770

6.  Indoor and outdoor PM mass and number concentrations at schools in the Athens area.

Authors:  E Diapouli; A Chaloulakou; N Mihalopoulos; N Spyrellis
Journal:  Environ Monit Assess       Date:  2007-04-26       Impact factor: 2.513

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.