Literature DB >> 24036679

Comparative morphometry of the antebrachial and crural interosseous membranes: preliminary study for the use of the crural interosseous membrane in the surgical repair of the antebrachial interosseous membrane tears.

Driss Elamrani1, Aurélien Aumar, Guillaume Wavreille, Christian Fontaine.   

Abstract

INTRODUCTION: Traumatic tears of the antebrachial interosseous membrane (AIOM) on its whole length are difficult to treat, particularly in the Essex-Lopresti syndrome. The number of ligamentoplasty techniques described in the literature witnesses the difficulty of its reconstruction and the absence of reliable and satisfying procedure. The aim of this study was to explore a new way of treatment, which consists in replacing the AIOM by the crural interosseous membrane (CIOM), harvested from the same patient.
MATERIALS AND METHODS: A morphometric study of the AIOM and CIOM has been conducted on both sides of 15 formalin preserved corpses (i.e. 30 AIOM and 30 CIOM). Studied data were: length of forearms and legs, length and width (at different locations) of the membranes, in situ and after harvesting, and orientation of their fibers. The thickness of membrane was also measured but only after harvesting.
RESULTS: Concerning the AIOM, the mean length was 13.3 cm in situ and 12.8 cm after harvesting. Its width was maximal at the union of middle and distal thirds with an average value of 1.7 cm in situ and 1.45 cm after harvesting. Mean thickness was 1 mm. Anterior fibers were oblique distally and medially (20.5° ± 0.95°), and posterior fibers were oblique distally and laterally (40° ± 3.4°). Concerning the CIOM, the mean length was 24.75 cm in situ and 23.9 cm after harvesting. Its width was maximal at the union of proximal and middle thirds with an average value of 2.3 cm in situ and 1.85 cm after harvesting. Mean thickness was 0.5 mm. Obliquity of its fibers was reverse of that of the AIOM: the anterior fibers were quite oblique distally and laterally (13° ± 2.6°), and the posterior fibers oblique were oblique distally and medially (24.2° ± 2.48°). DISCUSSION: From these results, one may conclude that the largest length and width of the CIOM allow its use as substitute for the injured AIOM. The orientation of its fibers should necessitate either its reversal while using the same side or the use of the CIOM of the opposite side; its relative sharpness could signify that its biomechanical properties could be worse. A biomechanical study is necessary to evaluate how this new way of replacing the AIOM could resist to the strains imposed on the forearm.

Entities:  

Mesh:

Year:  2013        PMID: 24036679     DOI: 10.1007/s00276-013-1199-9

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  26 in total

1.  [The radio-ulnar unit. Its functional importance in fractures of both bones of the forearm].

Authors:  A Kapandji
Journal:  Chir Main       Date:  1998

2.  Forearm interosseous membrane imaging and anatomy.

Authors:  Joseph C McGinley; Neil Roach; John P Gaughan; Scott H Kozin
Journal:  Skeletal Radiol       Date:  2004-08-25       Impact factor: 2.199

Review 3.  Management of injuries to the interosseous membrane.

Authors:  Julie E Adams; Scott P Steinmann; A Lee Osterman
Journal:  Hand Clin       Date:  2010-11       Impact factor: 1.907

Review 4.  Reconstruction of essex-lopresti injury of the forearm: technical note.

Authors:  George D Chloros; Ethan R Wiesler; Kathryne J Stabile; Anastasios Papadonikolakis; David S Ruch; Gary R Kuzma
Journal:  J Hand Surg Am       Date:  2008-01       Impact factor: 2.230

5.  Interosseous membrane of the forearm: an anatomical study of ligament attachment locations.

Authors:  Kazuo Noda; Akira Goto; Tsuyoshi Murase; Kazuomi Sugamoto; Hideki Yoshikawa; Hisao Moritomo
Journal:  J Hand Surg Am       Date:  2009-02-11       Impact factor: 2.230

6.  Anatomical and biomechanical study on the interosseous membrane of the cadaveric forearm.

Authors:  Xian-Hong Yi; Jun Pan; Xiao-Shan Guo
Journal:  Chin J Traumatol       Date:  2011-06-01

7.  The middle radioulnar joint and triarticular forearm complex.

Authors:  M Soubeyrand; V Wassermann; C Hirsch; C Oberlin; O Gagey; C Dumontier
Journal:  J Hand Surg Eur Vol       Date:  2011-03-29

8.  [Clinical anatomy of the interosseous arteries of the forearm].

Authors:  S Pahl; H M Schmidt
Journal:  Handchir Mikrochir Plast Chir       Date:  1994-09       Impact factor: 1.018

9.  Reconstructing the interosseous membrane: a technique using synthetic graft and endobuttons.

Authors:  Marlis T Sabo; Adam C Watts
Journal:  Tech Hand Up Extrem Surg       Date:  2012-12

10.  Results of bypasses to the anterior tibial artery through the interosseous membrane.

Authors:  G Illuminati; F G Calio; A Bertagni; V Martinelli
Journal:  Langenbecks Arch Surg       Date:  1998-08       Impact factor: 3.445

View more
  1 in total

1.  The crural interosseous membrane re-visited: a histological and microscopic study.

Authors:  Joseph Morley; Chenglei Fan; Kena McDermott; Caterina Fede; Emmett Hughes; Carla Stecco
Journal:  Eur J Transl Myol       Date:  2019-08-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.