Literature DB >> 24036363

High-throughput determination of nonsteroidal anti-inflammatory drugs in human plasma by HILIC-MS/MS.

Tetsuya Nemoto1, Xiao-Pen Lee, Takeshi Kumazawa, Chika Hasegawa, Masaya Fujishiro, Akemi Marumo, Yukiko Shouji, Katsunori Inagaki, Keizo Sato.   

Abstract

A simple and sensitive method was developed and validated here for the analysis of thirteen nonsteroidal anti-inflammatory drugs (NSAIDs) in human plasma samples by hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry (MS/MS). A small volume of plasma (20μL) spiked with compounds was diluted with 80μL of 10-mM ammonium acetate followed by a simple protein precipitation with 400μL of acetonitrile. After centrifugation, the clear supernatant extract was directly injected into the HILIC-MS/MS, without any solvent evaporation and reconstitution steps. The chromatographic separation of the NSAIDs was achieved on a Unison UK-Amino HILIC column (50mm×3mm i.d., particle size 3μm) with a linear gradient elution system composed of 10mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.4mL/min. The mass spectra obtained by HILIC-MS showed base peak ions due to [M+H](+) for indomethacin, oxaprozin, ketoprofen, alminoprofen, zaltoprofen, tiaprofenic acid, pranoprofen, and ketoprofen-d3 and due to [M-H](-) for etodolac, ibuprofen, diclofenac, fenoprofen, loxoprofen, naproxen, and ibuprofen-d3. Recoveries of these thirteen NSAIDs in plasma were 34.8-113% and the lower limits of quantitation were 0.125-1.25μg/mL. The intra- and interday coefficient of variations for all drugs in plasma were less than 14.6%. The data obtained from actual plasma determinations of zaltoprofen, ibuprofen, and diclofenac are also presented.
Copyright © 2013. Published by Elsevier B.V.

Entities:  

Keywords:  Human plasma; Hydrophilic interaction liquid chromatography (HILIC); Nonsteroidal anti-inflammatory drugs (NSAIDs); Tandem mass spectrometry (MS/MS); UK-Amino column

Mesh:

Substances:

Year:  2013        PMID: 24036363     DOI: 10.1016/j.jpba.2013.08.023

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  1 in total

1.  Determination of nonsteroidal anti-inflammatory drugs in human tear and plasma samples using ultra-fast liquid chromatography-tandem mass spectrometry.

Authors:  Makiko Hirosawa; Takehiko Sambe; Naoki Uchida; Xiao-Pen Lee; Keizo Sato; Shinichi Kobayashi
Journal:  Jpn J Ophthalmol       Date:  2015-06-19       Impact factor: 2.447

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.