Literature DB >> 24036176

Determination of amantadine and rimantadine in chicken muscle by QuEChERS pretreatment method and UHPLC coupled with LTQ Orbitrap mass spectrometry.

Hua Yan1, Xin Liu, Fengyun Cui, Huan Yun, Jianhui Li, Shuangyang Ding, Dajin Yang, Zhaohui Zhang.   

Abstract

A novel sample pretreatment method was developed for the quantitative determination of amantadine and rimantadine in chicken muscle tissues by ultra high performance liquid chromatography coupled with high resolution LTQ Orbitrap mass spectrometry (UHPLC-LTQ Orbitrap MS). The samples were pretreated by modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method, using acetonitrile (1% acetic acid, v/v) as extraction solution and C18 sorbent for clean-up. The separation was carried out on a Waters ACQUITY UPLC HSS T3 column (150mm×2.1mm, 1.8μm particle), using a mobile phase of acetonitrile and 0.1% aqueous formic acid solution. LTQ Orbitrap MS with resolving power of 60000 was applied for analysis of the samples. Amantadine and rimantadine were identified from their accurate mass (within 5ppm) and retention times from the acquired full-scan chromatogram and quantified by their peak areas. The linear range for the determination of the analytes was 1-100μg/kg. Limits of detection (LODs) for amantadine and rimantadine were 1.02μg/kg and 0.67μg/kg, respectively. The intra- and inter-day accuracy ranged from 87.5% to 102.4%, and 82.5% to 105.8% for amantadine, and 95.3% to 97.4%, and 89.4% to 93.2% for rimantadine, respectively. The precision of intra- and inter-day was between 3.9-6.3% and 5.95-13.9% for amantadine, 6.0-7.45% and 7.8-12.4% for rimantadine, respectively. Finally, the method was applied for the determination of these antiviral agents in routine samples, and amantadine residue was detected in some cases.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Amantadine; Chicken muscle tissues; LTQ Orbitrap MS; QuEChERS method; Rimantadine; UHPLC

Mesh:

Substances:

Year:  2013        PMID: 24036176     DOI: 10.1016/j.jchromb.2013.08.020

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  An electrodeposited molecularly imprinted quartz crystal microbalance sensor sensitized with AuNPs and rGO material for highly selective and sensitive detection of amantadine.

Authors:  Yaguang Yun; Mingfei Pan; Guozhen Fang; Ying Gu; Wenjun Wen; Rui Xue; Shuo Wang
Journal:  RSC Adv       Date:  2018-02-09       Impact factor: 4.036

Review 2.  Application of QuEChERS for Determining Xenobiotics in Foods of Animal Origin.

Authors:  Coralia V Garcia; Ahmed Gotah
Journal:  J Anal Methods Chem       Date:  2017-12-24       Impact factor: 2.193

3.  Sensitive and rapid determination of amantadine without derivatization in human plasma by LC-MS/MS for a bioequivalence study.

Authors:  Abhaysingh Bhadoriya; Shivprakash Rathnam; Bhavesh Dasandi; Dharmesh Parmar; Mallika Sanyal; Pranav S Shrivastav
Journal:  J Pharm Anal       Date:  2018-02-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.