Literature DB >> 24035852

Electrochemical immunosensor for the determination of insulin-like growth factor-1 using electrodes modified with carbon nanotubes-poly(pyrrole propionic acid) hybrids.

V Serafín1, L Agüí, P Yáñez-Sedeño, J M Pingarrón.   

Abstract

An amperometric immunosensor for the determination of the hormone insulin-like growth factor 1 (IGF1) is reported for the first time in this work. As electrochemical transducer, a multiwalled carbon nanotubes-modified glassy carbon electrode on which poly(pyrrole propionic acid) was electropolymerized was prepared. This approach provided a high content of surface confined carboxyl groups suitable for direct covalent binding of anti-IGF1 monoclonal antibody. A sandwich-type immunoassay using a polyclonal antibody labeled with peroxidase, hydrogen peroxide as the enzyme substrate and catechol as redox mediator was employed to monitor the affinity reaction. All the variables involved in the preparation of the modified electrode were optimized and the electrodes were characterized by electrochemical impedance spectroscopy and cyclic voltammetry. Moreover, the different experimental variables affecting the amperometric response of the immunosensor were also optimized. The calibration graph for IGF1 showed a range of linearity extending from 0.5 to 1000 pg/mL, with a detection limit, 0.25 pg/mL, more than 100 times lower than the lowest values reported for the ELISA immunoassays available for IGF1 (30 pg/mL, approximately). Excellent reproducibility for the measurements carried out with different immunosensors and selectivity against other hormones were also evidenced. A commercial human serum spiked with IGF1 at different levels between 0.01 and 10.0 ng/mL was analyzed with good results.
© 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemical immunosensor; Insuline-like growth factor 1; Poly(pyrrole propionic acid)

Mesh:

Substances:

Year:  2013        PMID: 24035852     DOI: 10.1016/j.bios.2013.08.021

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Voltammetric immunosensor assembled on carbon-pyrenyl nanostructures for clinical diagnosis of type of diabetes.

Authors:  Vini Singh; Sadagopan Krishnan
Journal:  Anal Chem       Date:  2015-02-23       Impact factor: 6.986

Review 2.  Carbon nanotubes in electrochemical, colorimetric, and fluorimetric immunosensors and immunoassays: a review.

Authors:  Hualin Yang; Wentao Xu; Xiongyan Liang; Yuying Yang; Yu Zhou
Journal:  Mikrochim Acta       Date:  2020-03-09       Impact factor: 5.833

3.  An alternative ready-to-use electrochemical immunosensor for point-of-care COVID-19 diagnosis using graphene screen-printed electrodes coupled with a 3D-printed portable potentiostat.

Authors:  Vitsarut Primpray; Wichayaporn Kamsong; Saithip Pakapongpan; Kanchanok Phochakum; Arissanan Kaewchaem; Assawapong Sappat; Anurat Wisitsoraat; Tanom Lomas; Adisorn Tuantranont; Chanpen Karuwan
Journal:  Talanta Open       Date:  2022-10-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.