Literature DB >> 24035649

Preoperative determination of ventriculostomy trajectory in ventriculoperitoneal shunt surgery using a simple modification of the standard coronal MRI.

Hyunjin Woo1, Dong-Hun Kang, Jaechan Park.   

Abstract

The aim of this technical report is to report a new method for ventriculoperitoneal (VP) shunt placement by determining the angle and distance of the proximal shunt catheter trajectory in the coronal plane using a simple modification of a standard coronal MRI. A modified coronal MRI (mcMRI) was taken in the coronal plane, which included Kocher's point and a point 1cm anterior to the tragus. Using this mcMRI, the trajectory from Kocher's point to a target in the frontal horn may be determined, and the angle and distance of the proximal shunt catheter trajectory may also be obtained. We identified a "safety angle" for catheter insertion, which avoided contact with any intraventricular structures. In addition, the length of the proximal catheter was calculated using the mcMRI, which we defined as the "safety depth." Twenty VP shunt surgeries were performed using an individual safety angle and safety length as determined by a preoperative mcMRI. The ventriculostomy was successful on the first attempt in all patients. The accurate placement of the proximal catheter was confirmed using a postoperative mcMRI. Only one patient demonstrated a track hemorrhage around the catheter path on CT scans. Follow-up evaluations were performed 3 to 12 months after the shunt surgery. The mcMRI protocol is a simple modification of the standard coronal MRI and may important for the determination of an accurate angle and distance of the proximal catheter during free-hand ventriculostomy for VP shunt. Crown
Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Modified coronal MRI; Safety angle; Safety depth; Ventriculoperitoneal shunt

Mesh:

Year:  2013        PMID: 24035649     DOI: 10.1016/j.jocn.2013.01.025

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  3 in total

1.  Optimizing accuracy of freehand cannulation of the ipsilateral ventricle for intracranial pressure monitoring in patients with brain trauma.

Authors:  Zhongyi Sun; Lin Wu; Zhixiong Liu; Weiming Zhong; Zhifeng Kou; Jinfang Liu
Journal:  Quant Imaging Med Surg       Date:  2020-11

2.  Adjustable Ghajar Guide Technique for Accurate Placement of Ventricular Catheters: A Pilot Study.

Authors:  Sang-Youl Yoon; Youngseok Kwak; Jaechan Park
Journal:  J Korean Neurosurg Soc       Date:  2017-08-30

3.  GAVCA Study: Randomized, Multicenter Trial to Evaluate the Quality of Ventricular Catheter Placement with a Mobile Health Assisted Guidance Technique.

Authors:  Ulrich-Wilhelm Thomale; Andreas Schaumann; Florian Stockhammer; Henrik Giese; Dhani Schuster; Stefanie Kästner; Alexander Sebastian Ahmadi; Manolis Polemikos; Hans-Christoph Bock; Leonie Gölz; Johannes Lemcke; Elvis Hermann; Martin U Schuhmann; Thomas Beez; Michael Fritsch; Berk Orakcioglu; Peter Vajkoczy; Veit Rohde; Georg Bohner
Journal:  Neurosurgery       Date:  2018-08-01       Impact factor: 4.654

  3 in total