Diagnostic accuracy of fingerstick β-hydroxybutyrate for ketonuria in pregnant women with nausea and vomiting.

Ian Ferguson1, Michael E Mullins.   

Abstract

OBJECTIVES: The aim of this study was to determine whether a rapid, fingerstick β-hydroxybutyrate (β-OHB) test predicts ketonuria in pregnant women with nausea and vomiting.
METHODS: A convenience sample of 82 pregnant women who presented to the Barnes-Jewish Hospital emergency department (ED) with complaints of nausea or vomiting were enrolled into an institutional review board-approved, prospective, observational study. Exclusion criteria were temperature of >38.3°C, altered mental status, prisoners, and >1 L of any intravenous (IV) fluid before screening. Subjects had fingerstick β-OHB tests, with results reported in increments of 0.1 mmol/L. Urine ketone results were made available once reported as part of standard care and varied from 0 (trace) to +4 values. Ketonuria was defined as a urine ketone value of 3+ or 4+ and was analyzed as a dichotomous, categorical variable. A contingency table and receiver operator characteristic (ROC) curve were constructed for comparing the β-OHB values to those urine ketone values for each patient.
RESULTS: Mean (±SD) β-OHB was 0.43 (±0.52) mmol/L, and median urine was 1+ for the cohort as a whole. The area under the ROC curve equaled 0.95. The sensitivity and specificity for a fingerstick test of >0.45 mmol/L were 89 and 94.5%, respectively. The positive likelihood ratio (LR) was 16, and the negative LR was 0.12.
CONCLUSIONS: Fingerstick β-OHB is a rapid and reliable diagnostic tool that correlates well with ketonuria and identifies ketonemia in pregnant women with nausea and vomiting. Fingerstick β-OHB testing has the potential to increase triage efficiency, shorten length-of-stay times, and positively affect patient outcomes in an ED setting.
© 2013 by the Society for Academic Emergency Medicine.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24033684     DOI: 10.1111/acem.12207

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  1 in total

1.  A novel device for collecting and dispensing fingerstick blood for point of care testing.

Authors:  Alexis F Sauer-Budge; Samuel J Brookfield; Ronald Janzen; Sarah McGray; Anna Boardman; Holger Wirz; Nira R Pollock
Journal:  PLoS One       Date:  2017-08-24       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.