Literature DB >> 2403233

Interference by haemolysis, icterus and lipaemia in assays on the Beckman Synchron CX5 and methods for correction.

A G Randall1, P Garcia-Webb, J P Beilby.   

Abstract

As part of an evaluation of a Synchron CX5 analyser (Beckman Instruments Inc, Brea, USA) we examined a range of tests for interference from haemolysis, bilirubin and lipaemia. Tests investigated were urea, creatinine, urate, total protein, albumin, calcium, total bilirubin, alkaline phosphatase (ALP), aspartate transaminase (AST), gamma-glutamyl transferase (GGT) and inorganic phosphate. Two types of interferences were found. One type is found on other analysers and represents analytical difficulties with the measurement of that particular analyte. The other type of interference was a consequence of the bichromatic optical system used on the CX-5. This latter group includes haemoglobin interference in the measurement of total protein and inorganic phosphate, and bilirubin interference with the measurement of total protein, glucose and inorganic phosphate. Lipaemia interfered with total protein, total bilirubin, inorganic phosphate, urate and glucose. Alternative and modified methods are proposed to improve the measurement of total protein, glucose, total bilirubin and inorganic phosphate. The use of the modified methods for glucose, inorganic phosphate and total bilirubin are limited, at this time, by an error in the calculation algorithm used by the analyser for two step or triggered chemistries, and to a lesser extent, by a reduction in sample throughput.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2403233     DOI: 10.1177/000456329002700411

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  3 in total

1.  Clinical experience with intravenous lipid emulsion for drug-induced cardiovascular collapse.

Authors:  Ann-Jeannette Geib; Erica Liebelt; Alex F Manini
Journal:  J Med Toxicol       Date:  2012-03

2.  Pseudohyperphosphatemia associated with high-dose liposomal amphotericin B therapy.

Authors:  Jason W Lane; Nadja N Rehak; Glen L Hortin; Theoklis Zaoutis; Philip R Krause; Thomas J Walsh
Journal:  Clin Chim Acta       Date:  2007-08-30       Impact factor: 3.786

3.  Lipemia Interferences in Biochemical Tests, Investigating the Efficacy of Different Removal Methods in comparison with Ultracentrifugation as the Gold Standard.

Authors:  Neda Soleimani; Sahand Mohammadzadeh; Fateme Asadian
Journal:  J Anal Methods Chem       Date:  2020-02-12       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.